WatchGuard Technologies | kA10H000000g3bvSAA

Cannot save configuration changes to Firebox configured with FireCluster and using Gateway Wireless Controller

Last update date:

6/27/2017

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

11.x

11.12.x

11.12.4

Fixed releases:

All

Description:

Issue

If you try to use Policy Manager v11.12.4 or higher to save a configuration change to a FireCluster and the FireCluster is also configured to use Gateway Wireless Controller and runs a version of Fireware lower than v11.12.2, the configuration change will fail with error message: The OS version on this device does not support configuring the Gateway Wireless Controller to use dynamic passphrases or the trust store mechanism when FireCluster is enabled. You must set a global passphrase and disable the trust store mechanism before you can save the configuration to this device.

Workaround/Solution

To avoid this issue, you must upgrade the FireCluster to Fireware v11.12.2 or higher, or use Policy Manager v11.12.2 to save configuration changes to the Firebox.