BugZero found this defect 2518 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
6/27/2017
Firebox M200
Firebox M300
Firebox M270
Firebox M370
Firebox M470
Firebox M570
Firebox M670
Firebox M290
Firebox M390
Firebox M400
Firebox M500
Firebox M440
All
Fireware
11.x
11.12.x
11.12.4
All
If you try to use Policy Manager v11.12.4 or higher to save a configuration change to a FireCluster and the FireCluster is also configured to use Gateway Wireless Controller and runs a version of Fireware lower than v11.12.2, the configuration change will fail with error message: The OS version on this device does not support configuring the Gateway Wireless Controller to use dynamic passphrases or the trust store mechanism when FireCluster is enabled. You must set a global passphrase and disable the trust store mechanism before you can save the configuration to this device.