Operational Defect Database

BugZero found this defect 2389 days ago.

WatchGuard Technologies | kA10H000000g3c7SAA

FireCluster does not automatically synchronize manually imported certificates

Last update date:

11/3/2017

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.0.x

Fixed releases:

All

Description:

Issue

When you manually import certificates on one member of a FireCluster, the certificates might not synchronize correctly to the other member of the cluster.

Workaround/Solution

When you manually import a certificate on a FireCluster, you must force a failover to the other cluster member, and import the certificate again.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More