Operational Defect Database

BugZero found this defect 3658 days ago.

WatchGuard Technologies | kA10H000000g3f4SAA

On some XTM devices configured to use PPPoE, if the MTU size is configured to be greater than 1492, received packets can be dropped

Last update date:

5/14/2014

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

11.x

11.10.x

11.10

11.10.1

11.10.2

11.10.3

11.10.4

11.10.5

11.10.6

11.10.7

Fixed releases:

All

Description:

Issue

On some XTM devices configured to use PPPoE, if the MTU size is configured to be greater than 1492, received packets can be dropped by the interface. Applicable devices include: XTM 5, XTM 8, XTM 800, XTM 1050, XTM 1500, XTM 2050.

Workaround/Solution

When you use PPPoE, configure an MTU size of 1492 or less.