Operational Defect Database

BugZero found this defect 3153 days ago.

WatchGuard Technologies | kA10H000000g3gASAQ

WatchGuard SSL appliance RDP resource fails to launch RDP client on Windows 10

Last update date:

10/1/2015

Affected products:

No affected products provided.

Affected releases:

Any/Unknown

Fixed releases:

All

Description:

Issue

This issue affects WatchGuard SSL appliance users only. If you launch an RDP tunnel resource from a computer installed with Windows 10, the Remote Desktop client on your computer will fail to launch with an Invalid connection file error message.The access client will still launch successfully and establish a tunnel.

Workaround/Solution

After the access client launches, you can manually launch remote desktop on your local computer and connect to the remote server by IP address.