BugZero found this defect 3175 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
9/9/2015
Firebox M200
Firebox M300
Firebox M270
Firebox M370
Firebox M470
Firebox M570
Firebox M670
Firebox M290
Firebox M390
Firebox M400
Firebox M500
Firebox M440
All
Fireware
11.x
11.10.x
11.10
11.10.1
11.10.2
11.10.3
11.10.4
11.10.5
11.10.6
11.10.7
v11.11
If you have Gateway Wireless Controller enabled on a Firebox device configured as part of a FireCluster, the Gateway Wireless Controller process runs only on the current Master. When the cluster fails over, the new Master forces a configuration update for any connected Access Points. Because of this, users connected to those Access Points may experience a short interruption of their wireless connection when the cluster fails over.