8/21/2015
Firebox M200
Firebox M300
Firebox M270
Firebox M370
Firebox M470
Firebox M570
Firebox M670
Firebox M290
Firebox M390
Firebox M400
Firebox M500
Firebox M440
All
Fireware
11.x
11.10.x
11.10.2
11.10.3
11.10.4
11.10.5
11.10.6
11.10.7
11.11.x
11.11
All
If you use Centralized Management, after you upgrade a fully managed device and your Management Server from Fireware v11.9.5 to Fireware v11.10.2, configuration changes will fail if the Firebox or XTM device has an external interface configured with PPPoE.
If you change the configuration of the device to Basic Managed mode, save that change, and then change the device back to Fully Managed mode, configuration changes will work correctly.