Operational Defect Database

BugZero found this defect 3194 days ago.

WatchGuard Technologies | kA10H000000g3hOSAQ

Configuration changes to fully managed device with PPPoE interfaces fail after upgrade to 11.10.2

Last update date:

8/21/2015

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

11.x

11.10.x

11.10.2

11.10.3

11.10.4

11.10.5

11.10.6

11.10.7

11.11.x

11.11

Fixed releases:

All

Description:

Issue

If you use Centralized Management, after you upgrade a fully managed device and your Management Server from Fireware v11.9.5 to Fireware v11.10.2, configuration changes will fail if the Firebox or XTM device has an external interface configured with PPPoE.

Workaround/Solution

If you change the configuration of the device to Basic Managed mode, save that change, and then change the device back to Fully Managed mode, configuration changes will work correctly.

Additional Resources / Links

Share: