Operational Defect Database

BugZero found this defect 3089 days ago.

WatchGuard Technologies | kA10H000000g3hRSAQ

Cannot import intermediate certificate if Root CA was imported as Trusted CA for Proxies

Last update date:

12/4/2015

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

11.x

11.10.x

11.10

11.10.1

11.10.2

11.10.3

11.10.4

11.10.5

11.10.6

11.10.7

Fixed releases:

All

Description:

Issue

If you imported a Root CA certificate with the Trusted CA for Proxies option, certificate validation will fail for any certificate or intermediate CA signed by that Root CA.

Workaround/Solution

To resolve this issue, import the Root CA certificate with the IPSec, Web Server, Other option before you try to import any certificates signed by that Root CA certificate.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More

Search:

...