WatchGuard Technologies | kA10H000000g3jrSAA

Managed BOVPN tunnels fail when the managed device name includes “&”

Last update date:

11/12/2014

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

11.x

11.1.x

11.10.x

11.10

11.10.1

11.10.2

11.10.3

11.10.4

11.10.5

11.10.6

Fixed releases:

All

Description:

Issue

If your Firebox or XTM device configuration includes a Managed Branch Office VPN in which one of the endpoint devices has a Managed Device name that includes an ampersand (&) character, that Branch Office VPN will fail to establish. In the log messages, the error message looks like this:Error: 2014-09-29 12:03:49 iked (203.0.113.2<->198.51.100.2)AggrMode Wait SA: invalid hash for PSK, auth failed Debug

Workaround/Solution

Do not use ampersand (&) characters in the name of the managed device.

Additional Resources / Links

Share: