Operational Defect Database

BugZero found this defect 3397 days ago.

WatchGuard Technologies | kA10H000000g3k2SAA

Inbound SMTP over TLS fails on some XTM 21-23 devices when you save configuration with more current WSM

Last update date:

1/30/2015

Affected products:

No affected products provided.

Affected releases:

All

Fireware

11.x

11.6.x

11.6

11.6.1

11.6.3

11.6.5

11.6.6

11.7.x

11.7

11.7.2

Fixed releases:

All

Description:

Issue

If you use WatchGuard System Manager v11.8.x or later to manage an XTM 21, 22, or 23 device installed with Fireware XTM v11.6.x, inbound SMTP over TLS will fail. In Traffic Monitor, you may see a message like this: 2015-01-19 13:43:02 cfm apply_filter inWork FAILED error:14090086:SSL routines:SSL3_GET_SERVER_CERTIFICATE:certificate verify failed Debug

Workaround/Solution

Use WatchGuard System Manager 11.7.4 or Web UI to manage these devices.