Cannot configure Access Portal Web Application with Policy Manager

Last update date:

4/9/2020

Affected products:

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M400

Firebox M500

Firebox M440

Firebox M4600

Firebox M5600

FireboxV

Firebox Cloud

Affected releases:

All

Fireware

12.x

12.5.x

Fixed releases:

All

Description:

Issue

If you configure Mobile VPN to use a non-standard port (for example TCP port 8443), you cannot use Policy Manager to add an external web application for Access Portal. Policy Manager will not allow you to save the configuration.

Workaround/Solution

If you configure Mobile VPN to use a non-standard port, and use Fireware Web UI to add the external web application for Access Portal, you see a message that looks like this:The URL cannot be mapped to an internally hosted URL because Access Portal uses port 8443.You can safely ignore the error message because you are adding an externally hosted URL.