Operational Defect Database

BugZero found this defect 496 days ago.

WatchGuard Technologies | kA16S000000Bc6FSAS

Policy Manager and FSM cannot connect to Firebox that uses an EC certificate as the web server certificate

Last update date:

1/9/2023

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.0.x

12.1.x

12.1

12.1.1

12.1.3

12.10.x

12.2.x

12.3.x

12.4.x

Fixed releases:

v12.9.4

Description:

Issue

Policy Manager and FSM fail to connect to a Firebox with a handshake error if the Firebox web server certificate was generated with an elliptic curve (EC) private key.

Workaround/Solution

There is no workaround for the issue. We recommended that you use an RSA certificate for the Firebox web server certificate.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More

Search:

...