BOVPNs might fail in FireCluster configurations after a scheduled reboot

Last update date:

1/17/2023

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.0.x

12.1.x

12.1

12.1.1

12.1.3

12.10.x

12.2.x

12.3.x

12.4.x

Fixed releases:

v12.9 Update 1

Description:

Issue

After a scheduled reboot of devices in a FireCluster configuration, BOVPNs might fail to start. The problem might not affect all BOVPNs configured. When this issue occurs, you might see these types of log messages:Jan 01 00:17:06 iked[xxxx]: (x.x.x.x<->x.x.x.x)ikeSendToWithPktInfo: sendmsg failed, ifindex:x - error:Operation not permitted(1)

Workaround/Solution

Manually reboot the cluster members.