BugZero found this defect 1014 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
8/10/2021
Firebox M200
Firebox M300
Firebox M270
Firebox M370
Firebox M470
Firebox M570
Firebox M670
Firebox M290
Firebox M390
Firebox M400
Firebox M500
Firebox M440
All
Fireware
12.x
12.7.x
v12.7.2
After you upgrade a Firebox to Fireware v12.7.1, users might not see secondary authentication servers in the Authentication Servers drop-down list on the Fireware Web UI Login page. Only Firebox-DB is available in the drop-down list.
In WSM, select Setup > Authentication > Authentication Settings. The Authentication Settings dialog box opens.From the Default authentication server used to log in to Fireware Web UI drop-down list, select a different default authentication server.Save the configuration.In the Authentication Settings dialog box, from the Default authentication server used to log in to Fireware Web UI drop-down list, select the preferred default authentication server.Save the configuration. The Web UI Login page now shows all available authentication servers.