Operational Defect Database

BugZero found this defect 782 days ago.

WatchGuard Technologies | kA16S000000O6shSAC

XTMv devices with less than 4GB RAM that run v12.1.3 Update 8 might not pass integrity check and fail to boot

Last update date:

4/7/2022

Affected products:

XTMv

Affected releases:

All

Fireware

12.x

12.1.x

12.1.3

Fixed releases:

v12.1.3 U8 Build 658867

Description:

Issue

XTMv devices that run Fireware v12.1.3 Update 8 can fail to boot after initial bootup if they are allocated less than 4GB of RAM. When this occurs, the system console shows the message: Signature did not verify. Error: integrity check failed Note: A similar known issue affects FireboxV devices that run Fireware v12.8. For more information, see https://techsearch.watchguard.com/KB?type=Known%20Issues&SFDCID=kA16S000000O6tkSAC&lang=en_US .

Workaround/Solution

Before you upgrade to Fireware v12.1.3 Update 8 or before you deploy a new XTMv appliance, allocate 4GB or more RAM to the XTMv virtual appliance in HyperV or VMWare.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More

Search:

...