BugZero found this defect 782 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/7/2022
XTMv
All
Fireware
12.x
12.1.x
12.1.3
v12.1.3 U8 Build 658867
XTMv devices that run Fireware v12.1.3 Update 8 can fail to boot after initial bootup if they are allocated less than 4GB of RAM. When this occurs, the system console shows the message: Signature did not verify. Error: integrity check failed Note: A similar known issue affects FireboxV devices that run Fireware v12.8. For more information, see https://techsearch.watchguard.com/KB?type=Known%20Issues&SFDCID=kA16S000000O6tkSAC&lang=en_US .
Before you upgrade to Fireware v12.1.3 Update 8 or before you deploy a new XTMv appliance, allocate 4GB or more RAM to the XTMv virtual appliance in HyperV or VMWare.