BugZero found this defect 789 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
3/31/2022
FireboxV
All
Fireware
12.x
12.8.x
All
FireboxV devices that run Fireware v12.8 can fail to boot after initial bootup if they are allocated less than 2GB of RAM. When this occurs, the system console shows the message: Signature did not verify. Error: integrity check failed Note: A similar known issue affects XTMv devices that run Fireware v12.1.3 Update 8. For more information, see https://techsearch.watchguard.com/KB?type=Known%20Issues&SFDCID=kA16S000000O6shSAC&lang=en_US.
Shut down the FireboxV appliance.Update the allocated memory to 4GB or more. Boot up the FireboxV appliance.