WatchGuard Technologies | kA16S000000SNKxSAO

Crashes occur when link aggregation interface is used for FireCluster management

Last update date:

10/14/2021

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

11.x

11.1.x

11.10.x

11.10

11.10.1

11.10.2

11.10.3

11.10.4

11.10.5

11.10.6

Fixed releases:

v12.8

Description:

Issue

When you configure an Active/Passive FireCluster with link aggregation (LA), issues can occur if you select the link aggregation interface as the management interface of the FireCluster.In this scenario, the FireCluster cannot associate the link aggregation interface (or configured VLANs that are part of the link aggregation interface) to the management interface, which can prevent management of the FireCluster or potentially cause crashes.

Workaround/Solution

Use a VLAN or other interface that is not part of the link aggregation interface as the management interface of the FireCluster.