Operational Defect Database

BugZero found this defect 1123 days ago.

WatchGuard Technologies | kA16S000000XeEvSAK

Remote Access Point VPN configuration requires commas for Firebox certificate common name

Last update date:

4/22/2021

Affected products:

Wi-Fi Cloud

Affected releases:

All

Wi-Fi Cloud

Fixed releases:

All

Description:

Issue

When you configure an IPSec tunnel interface in Wi-Fi Cloud for use with the Remote Access Point VPN and a Firebox, you are required to use the Firebox certificate as the Remote Authentication Method for the endpoint in the Remote (Right) section of the tunnel configuration.When you copy the Firebox certificate Common Name (Subject Name) from the Firebox IKEv2 VPN Phase 1 configuration, it does not include the commas. For example: o=WatchGuard ou=Fireware cn=ikemuvpn Server

Workaround/Solution

In the Tunnel Interface settings in Wi-Fi Cloud, make sure you edit the Identifier field to include the commas. For example: o=WatchGuard, ou=Fireware, cn=ikemuvpn Server

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Open

Learn More

Search:

...