Operational Defect Database

BugZero found this defect 1063 days ago.

WatchGuard Technologies | kA16S000000XeeFSAS

Configuration from USB drive: External interface IP address not set after reboot

Last update date:

6/21/2021

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.0.x

12.1.x

12.1

12.1.1

12.1.3

12.10.x

12.2.x

12.3.x

12.4.x

Fixed releases:

All

Description:

Issue

An interface configuration settings file downloaded from WatchGuard Cloud (ip_rapid.csv) cannot be read from the USB drive if the file uses the default encoding. The rapid_ip.err.[serial-number] file written to the USB drive contains the error message: "No matching entry found in the config file".

Workaround/Solution

Open the downloaded configuration settings file in a text editor and resave it with ANSI encoding instead of UTF-8. Reconnect the USB drive to the Firebox and reboot.