Operational Defect Database

BugZero found this defect 213 days ago.

WatchGuard Technologies | kA16S000000bykiSAA

WSM v12.10 shows incorrect Application Control categories for devices that run v12.5.11 or lower

Last update date:

10/19/2023

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.10.x

12.5.x

Fixed releases:

All

Description:

Issue

In Fireware v12.5.12, the categories of applications in Application Control changed.When you use WSM v12.10 to manage a Firebox that runs Fireware v12.5.11 or lower, Policy Manager shows the Application Control categories for devices that run v12.10 or higher instead of the categories for v12.5.11 or lower.

Workaround/Solution

There are two possible workarounds for this issue: Upgrade the Firebox to Fireware v12.5.12.Use Fireware Web UI to configure Application Control on devices that run Fireware v12.5.11 or lower.