java.lang.NumberFormatException error message in Firebox System Manager 12.10.1

Last update date:

12/7/2023

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.10.x

Fixed releases:

v12.10.2

Description:

Issue

When you connect to a Firebox with Firebox System Manager v12.10.1, you see a warning message with the text "An error occurred while refreshing 'Front Panel': java.lang.NumberFormatException: For input string:", followed by a date. This error is caused by invalid data in the mobile VPN user authentication data returned by the Firebox. It does not impact a user's ability to authenticate to the mobile VPN or get access to VPN resources.

Workaround/Solution

There is no workaround at this time. The error message only appears on the Front Panel or Authenticated Users tabs in FSM. To prevent future warnings, reduce the polling interval or pause FSM.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More