Operational Defect Database

BugZero found this defect 370 days ago.

WatchGuard Technologies | kA16S00000110qmSAA

SNMP polling for interface information returns "No Such Instance" error on T20-W/T40-W with Wi-Fi enabled

Last update date:

5/15/2023

Affected products:

Firebox T20

Firebox T40

Affected releases:

All

Fireware

12.x

12.9.x

Fixed releases:

v12.10

Description:

Issue

On T20-W and T40-W Fireboxes with built-in Wi-Fi enabled, sensors or specific OIDs that include interface information might return a "No Such Instance" error when polled for. Sample OIDs include: 1.3.6.1.2.1.2.2.1.1 Description: ifIndex OBJECT-TYPE1.3.6.1.2.1.31.1.1.1.1 Description The textual name of the interface.1.3.6.1.2.1.25.3.2.1.3 Description A textual description of this device

Workaround/Solution

No workaround exists at this time.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More