After High Availability with Stateful Failover is set up, disabling then re-enabling Stateful Failover, and keeping the same Control and Data interfaces, will cause the secondary unit to stay in ELECTION state and access to the primary firewall will be lost. (This issue only affects NSa 4700, NSa 5700, NSa 6700, NSsp 10700, NSsp 11700, and NSsp 13700 models.) The status will recover after fifteen minutes or after the firewalls have been shut down and restarted.

Last update date:

6/4/2020

Affected products:

NSa 2700

NSa 3700

NSa 4700

NSa 5700

NSa 6700

NSsp 10700

NSsp 11700

NSsp 13700

NSv 270

NSv 470

NSv 870

TZ270

Affected releases:

7.0.1-5095

7.0.1-5111

Fixed releases:

No fixed releases provided.

Description:

NSA 4700, NSA 5700, NSA 6700, NSsp 10700, NSsp 11700, NSsp 13700 models only: After High Availability with Stateful Failover is set up, disabling and then re-enabling Stateful Failover, and keeping the same Control and Data interfaces, will cause the secondary unit to stay in Election state and access to the primary unit will be lost. The status will recover after fifteen minutes or after the units have been power cycled.. After High Availability with Stateful Failover is set up, disabling then re-enabling Stateful Failover, and keeping the same Control and Data interfaces, will cause the secondary unit to stay in ELECTION state and access to the primary firewall will be lost. (This issue only affects NSa 4700, NSa 5700, NSa 6700, NSsp 10700, NSsp 11700, and NSsp 13700 models.) The status will recover after fifteen minutes or after the firewalls have been shut down and restarted.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Known

Learn More

Search:

...