SOSV-5481 | Unavailability message "Packet needs to be fragmented but DF set" with numbered VPN tunnel for MTU test. | 2020-06-04 00:00:00 | Read more |
SOSV-5486 | NSv200 virtual machine memory utilization steadily increases to +95% and rebooting. | 2020-06-04 00:00:00 | Read more |
SOSV-5503 | Unauthenticated SonicOS out of bounds write denial of service vulnerability. | 2020-06-04 00:00:00 | Read more |
SOSV-5504 | Timing Oracle in RSA Decryption (CVE-2022-4304). | 2020-06-04 00:00:00 | Read more |
SOSV-5505 | Use after free following BIO_new_NDEF (CVE-2023-0215). | 2020-06-04 00:00:00 | Read more |
SOSV-5506 | General name X.400 address type confusion in X.509 (CVE-2023-0286). | 2020-06-04 00:00:00 | Read more |
SOSV-5507 | CFS blocks a few websites on Edge and Chrome. Drop code: "Enforced Content Filter Policy" (the same fix with GEN7-27088 and GEN6-2869). | 2020-06-04 00:00:00 | Read more |
SOSV-5508 | Unable to ping LAN IPv6 interface from the NetExtender client (Same fix with GEN7-5970). | 2020-06-04 00:00:00 | Read more |
SOSV-5514 | Possible MFA OTP brute force attack. | 2020-06-04 00:00:00 | Read more |
GEN7-21392 | The Real Time Monitor does not display all of the actual traffic going through the firewall. | 2020-06-04 00:00:00 | Read more |
GEN7-30560 | In response to a user accessing the WAN from LAN using a security rule containing the group Everyone, the device shows an undetermined error when trying to change the password afte... | 2020-06-04 00:00:00 | Read more |
GEN7-32261 | OSPFv3/RIPng cannot be established over trunked VLAN or sub-VLAN interfaces. | 2020-06-04 00:00:00 | Read more |
GEN7-33585 | IPv6 VPN does not work when using a VLAN interface. | 2020-06-04 00:00:00 | Read more |
GEN7-33914 | The value of OSPF interface Auto-Cost is incorrect for 40G interfaces. | 2020-06-04 00:00:00 | Read more |
GEN7-34690 | The Resolved Address is not displayed even though the domain is resolved when using IPv6 DNS server. | 2020-06-04 00:00:00 | Read more |
GEN7-35241 | If two IPv6 WAN interfaces are configured, configuring the second interface in IPv6 static mode causes the error Command 'dns primary xxxxx::xxx:xxxx:xxxx::xxxx' does not match to ... | 2020-06-04 00:00:00 | Read more |
GEN7-36708 | Unable to load a build or exp file when doing out-of-band management using the MGMT port. A different port needs to be used for out-of-band management or the system used by the adm... | 2020-06-04 00:00:00 | Read more |
GEN7-37068 | System logs and event logs are not being processed for Website Blocked when Stealth Mode is enabled. The counter remains at 0. | 2020-06-04 00:00:00 | Read more |
GEN7-37135 | LDAP sync fails while waiting for a reply from the LDAP server. | 2020-06-04 00:00:00 | Read more |
GEN7-37387 | In an High Availability environment, the internal default OSPF route disappears from the active firewall when OSPF has been configured with LSA tracking for the default route and d... | 2020-06-04 00:00:00 | Read more |
GEN7-37454 | Dynamic routes are deleted on Slave blades for active firewall after disabling Stateful Synchronization option. The packets are dropped due to IP Spoof check error. | 2020-06-04 00:00:00 | Read more |
GEN7-37862 | Syslog packets are not generated over a VPN tunnel when two syslog servers have been enabled. | 2020-06-04 00:00:00 | Read more |
GEN7-38631 | The High Availability link may not come up intermittently after upgrading the firmware. | 2020-06-04 00:00:00 | Read more |
GEN7-39016 | The Arp Entry is not clear after it reaches after the counter reaches 0 minutes. | 2020-06-04 00:00:00 | Read more |
GEN7-39744 | Traffic is forwarded when a security rule set to Deny/Discard in Wire Mode. | 2020-06-04 00:00:00 | Read more |
GEN7-39788 | Under some conditions, the Content Filtering Service (CFS) will not block a Deny rated domain when a TCP Window Update packet is received after the connection. Instead, the policy ... | 2020-06-04 00:00:00 | Read more |
GEN7-39993 | Packets matching a Security Policy with Action Profile set to SSO Bypass reports Packet Dropped - policy user sso needed in the log. This can be a false-positive that can lead to c... | 2020-06-04 00:00:00 | Read more |
GEN7-35781 | Adding an ECMP route with Tunnel VPN as the last interface fails when the Gateway Number is either 3 or 4. | 2020-06-04 00:00:00 | Read more |
GEN7-36684 | A design change now allows special management (no user policy required) only using the MGMT port on appliances that do not have a management port. For the appliances that have a ma... | 2020-06-04 00:00:00 | Read more |
GEN7-40273 | Management is allowed using HTTPS/SSH through a site-to-site VPN policy when HTTPS/SSH Management via this SA is disabled in the VPN policy | 2020-06-04 00:00:00 | Read more |
GEN7-40300 | When changing the SSLVPN client Network Address IPV4 pool, the change may intermittently not be completed even when it shows that change was successful. | 2020-06-04 00:00:00 | Read more |
GEN7-40369 | An error may be displayed when clicking the Apply button on the LDAP Mirror configuration page in a High Availability configuration when a valid local certificate is removed from t... | 2020-06-04 00:00:00 | Read more |
GEN7-28162 | Access points connected to the firewall failed to successfully complete. | 2020-06-04 00:00:00 | Read more |
GEN7-29806 | Check Network Settings tests fail when all internet traffic is routed through VPN that is defined using an unnumbered tunnel interface. | 2020-06-04 00:00:00 | Read more |
GEN7-35191 | The firewall fails to send the SFR file to Network Security Manager (NSM). | 2020-06-04 00:00:00 | Read more |
GEN7-35328 | When logging in to a firewall as a read-only administrator, a warning is displayed that informs the user that they cannot preempt the existing administrator and to choose between D... | 2020-06-04 00:00:00 | Read more |
GEN7-36529 | The presence of a large number of FQDN address objects can cause high CPU utilization. One effect of this is the ULA page to failing to respond for user authentication. | 2020-06-04 00:00:00 | Read more |
GEN7-36720 | The firewall might automatically restart after submitting a one-time password (OTP) received by email in the NetExtender user OTP window. | 2020-06-04 00:00:00 | Read more |
GEN7-37020 | The Observed Threats Data displayed on the Dashboard does not match the data shown in the AppFlow Report. | 2020-06-04 00:00:00 | Read more |
GEN7-37021 | The front panel indicator of an interface does not indicate that it is inactive when the corresponding L2 switching LAG aggregator port becomes unavailable. | 2020-06-04 00:00:00 | Read more |
GEN7-37091 | The BWM Monitor page displays as a blank page when there is a difference between the system time and the BWM clock time, resulting in a timeline offset in management interface disp... | 2020-06-04 00:00:00 | Read more |
GEN7-37172 | The Guest Services > Custom Page authentication does not display the custom texts or URLs. | 2020-06-04 00:00:00 | Read more |
GEN7-37403 | The firewall does not accept an LDAP server name that begins with a number. | 2020-06-04 00:00:00 | Read more |
GEN7-37456 | MAC filtering and options did not work as expected, including not being able to add a client to a custom allow group when the MAC filter is disabled. If an existing Address Object ... | 2020-06-04 00:00:00 | Read more |
GEN7-37564 | A DPI-SSL server-enabled firewall is not sending server hello and server certificate packets to the client. The website times out when accessed. | 2020-06-04 00:00:00 | Read more |
GEN7-37668 | On the Network > Interfaces page, when expanding the Zones field, the scaling is not working. The fields do not all move over, particularly sub-interfaces with long names. | 2020-06-04 00:00:00 | Read more |
GEN7-37693 | The Report Events via IPFIX is missing from the system logs in current firewalls. This data was available in legacy devices . | 2020-06-04 00:00:00 | Read more |
GEN7-37763 | Capture ATP Block Until Verdict is not blocking some file downloads. Support for Capture ATP-eligible files transferred over HTTP as gzip files was recently added.. | 2020-06-04 00:00:00 | Read more |
GEN7-37994 | When registering a NSv firewall, the system would report a successful registration, but did not update the licenses on the firewall. | 2020-06-04 00:00:00 | Read more |
GEN7-38129 | An incorrect validation in the health check email body text causes the Log Mail Advanced Settings page to not function when clicking on Advanced. | 2020-06-04 00:00:00 | Read more |
GEN7-38156 | Administrator was unable to access the management interface X0 management IP using an SSL-VPN connection over IPv6 to WAN IP on the firewall. | 2020-06-04 00:00:00 | Read more |
GEN7-38194 | Disabling virtual MAC for High Availability causes the firewall to drop the ARP request generated by itself. The device could not then be managed using the WAN interface and LAN to... | 2020-06-04 00:00:00 | Read more |
GEN7-38265 | No audio was present when connecting with an HTML5 RDP bookmark in SSL-VPN. | 2020-06-04 00:00:00 | Read more |
GEN7-38594 | A conflict between the log module and IPFIX causes the firewall to restart. | 2020-06-04 00:00:00 | Read more |
GEN7-38663 | The size limit of custom header value has been adjusted to 512 characters. | 2020-06-04 00:00:00 | Read more |
GEN7-38743 | Content Filtering Service (CFS) policies based on AD Groups do not work when using TSA agent for SSO authentication. | 2020-06-04 00:00:00 | Read more |
GEN7-39015 | The firewall might automatically restart after submitting a one-time password (OTP) received by email in the NetExtender user OTP window. | 2020-06-04 00:00:00 | Read more |
GEN7-39024 | Warnings are displayed when using DPI-SSL because of the expiration of the built-in Intermediate certificate (DigiCert SHA2 Secure Server CA). | 2020-06-04 00:00:00 | Read more |
GEN7-39347 | A warning is displayed when logging in as a read-only administrator when using the MGMT interface. | 2020-06-04 00:00:00 | Read more |
GEN7-39385 | The DDNS profile for changeip.com displays a Network Error warning when configuring a profile because of a change in ChangeIP's API. | 2020-06-04 00:00:00 | Read more |
GEN7-39406 | The Per Event IPFIX control states in the Event/System Log Settings could not enabled or disabled. | 2020-06-04 00:00:00 | Read more |
GEN7-39469 | The firewall may restart when an LDAP user that is part of Administrators group tries to log in to the firewall. | 2020-06-04 00:00:00 | Read more |
GEN7-36178 | FTP automation fails if the server response is longer than 2 seconds. | 2020-06-04 00:00:00 | Read more |
GEN7-36194 | If the names of two VPN tunnel interfaces begin with the same first 16 characters, Advanced Routing support cannot be enabled on either interface. | 2020-06-04 00:00:00 | Read more |
GEN7-37226 | 10G interfaces and 1G interfaces are allowed by management interface to be put into an L2 Static LAG Group even though this configuration setting should not be allowed. | 2020-06-04 00:00:00 | Read more |
GEN7-37508 | When importing a configuration that has WAN to TrustZone secure Wire Mode interfaces configured, the traffic is not blocked. | 2020-06-04 00:00:00 | Read more |
GEN7-39850 | The warning message gateway must be default is displayed when choosing an 6to4AutoTunnel interface for an IPv6 Policy Based Route for the gateway. | 2020-06-04 00:00:00 | Read more |
GEN7-40352 | Adding a Content Filter Profile Objects when selecting block for '29. Search Engines and Portals' causes the error 'Command 'category "1. Violence/Hate/Racism" block' does not matc... | 2020-06-04 00:00:00 | Read more |
GEN7-40390 | In a NSv L3 High Availability configuration, changing the X0 IP address causes the Primary to lose its connection with Secondary. Restarting the firewall is required to restore the... | 2020-06-04 00:00:00 | Read more |
GEN7-40520 | After upgrading the firmware on a firewall, the firewall reports that it is not synchronized to Network Security Manager (NSM). | 2020-06-04 00:00:00 | Read more |
GEN7-40554 | Importing preferences from a NSa 5600 to a NSa 6700 fails if a SSO policy are not configured correctly. | 2020-06-04 00:00:00 | Read more |
GEN7-29243 | SNMP Queries are taking a long time to complete when there are Portshielded Interfaces and querying interface-related object identifiers. | 2020-06-04 00:00:00 | Read more |
GEN7-31345 | The SMB File transfer speed over VPN drops significantly when the files are copied to a LAN device behind an NSv instance in Azure. | 2020-06-04 00:00:00 | Read more |
GEN7-32492 | The OSPF MTU of Unnumbered Tunnel Interfaces is set to a fixed value of 1446, which may not always be correct. | 2020-06-04 00:00:00 | Read more |
GEN7-32624 | A device may be unable to get a WAN IP from the ISP from a PPPoE connection after the device is restarted. | 2020-06-04 00:00:00 | Read more |
GEN7-33153 | Appliances now require that the administrator must change the administrator password if the appliance is started from factory default settings or if the default administrator passw... | 2020-06-04 00:00:00 | Read more |
GEN7-33218 | Guest users are not redirected to the captive portal authentication page. | 2020-06-04 00:00:00 | Read more |
GEN7-33655 | When the user authentication method is set to RADIUS, even if the Read-Only Admins Group belongs to the user's group, the user can log in as a Full Administrator when logging in to... | 2020-06-04 00:00:00 | Read more |
GEN7-34401 | DHCP via IP Helper is not working over IPSec VPN in SD-WAN configurations. | 2020-06-04 00:00:00 | Read more |
GEN7-34875 | NSa 3700 only: The appliance stops passing traffic and becomes inaccessible through the LAN interface after a few months in operation. | 2020-06-04 00:00:00 | Read more |
GEN7-35282 | The download speed is slower than expected when Bandwidth Management is enabled on access rules when the TCP advertised window is not large enough. | 2020-06-04 00:00:00 | Read more |
GEN7-35355 | LDAP users of the format domain\username are unable to authenticate when using Time-based One-Time Password authentication. | 2020-06-04 00:00:00 | Read more |
GEN7-35356 | NSa 2700 only: An appliance may become inaccessible after being active for some time because of a deadlock state between the routing and VPN modules. | 2020-06-04 00:00:00 | Read more |
GEN7-35478 | The system log displays an incorrect fw_action for the message Syslog Website Accessed. | 2020-06-04 00:00:00 | Read more |
GEN7-35530 | When configuring a High Availability environment, both the Primary and Secondary device both became Active and cannot discover its peer firewall for synchronization or failover. | 2020-06-04 00:00:00 | Read more |
GEN7-35651 | An option was added on the diagnostics page for GEO-IP that allows administrators to drop TCP handshakes coming from an IP address that originates from a blocked country. Synchroni... | 2020-06-04 00:00:00 | Read more |
GEN7-35761 | On the management user interface, the Storage LED may display as being Off, but the light remains lit on the device. | 2020-06-04 00:00:00 | Read more |
GEN7-35947 | NSa 4700, NSa 5700, NSa 6700, NSsp 10700, NSsp 11700, and NSsp 13700 models only: If an administrator is logged into both the Safe Mode user interface and the Safe Mode command-lin... | 2020-06-04 00:00:00 | Read more |
GEN7-36244 | The management interface shows that 10G interfaces (X29-X33) are still active in the front panel display with a TwinAX cable connected and shutting down the interfaces through the ... | 2020-06-04 00:00:00 | Read more |
GEN7-36461 | A firewall may reboot when multiple Access Rules are deleted when the source zone is in a custom DMZ and the destination zone is a VPN. | 2020-06-04 00:00:00 | Read more |
GEN7-36535 | When using a DPI-SSL server, the intermediate certificate is not being sent. | 2020-06-04 00:00:00 | Read more |
GEN7-36602 | The administrator cannot disable RADIUS proxy forwarding when the user-name attribute format is set to Other in the SSO configuration. | 2020-06-04 00:00:00 | Read more |
GEN7-36610 | Cannot connect to WiFi when both SSID suppression and MAC filtering are enabled. | 2020-06-04 00:00:00 | Read more |
GEN7-36631 | In High Availability configurations, for Flow Reporting on Network Security Manager for firewalls, the secondary device sends flow logs with the secondary serial number instead of ... | 2020-06-04 00:00:00 | Read more |
GEN7-36703 | Security Headers have been added for servers. | 2020-06-04 00:00:00 | Read more |
GEN7-36790 | NSa 4700, NSa 5700, NSa 6700, NSsp 10700, NSsp 11700, and NSsp 13700 models only: An issue was intermittently experienced when an appliance could not be successfully upgraded using... | 2020-06-04 00:00:00 | Read more |
GEN7-36919 | When using the Wizard to create a NAT policy, a Service Group gets created for service explicitly named 'any' instead of using the default any Service Group. | 2020-06-04 00:00:00 | Read more |
GEN7-36965 | Global VPN client RCF import fails when password contains special chars, such as #. | 2020-06-04 00:00:00 | Read more |
GEN7-37018 | When an LDAP user without administration privileges attempts to log in from a LAN, the error message Unknown error is displayed instead of a more specific reason, such as not enoug... | 2020-06-04 00:00:00 | Read more |
GEN7-37044 | Improper Restriction of Excessive MFA Attempts | 2020-06-04 00:00:00 | Read more |
GEN7-37095 | For TZ 270, TZ 370, and TZ 470 models only: the Enable Stateful Synchronization option is not displayed within the management interface for High Availability. If this option was en... | 2020-06-04 00:00:00 | Read more |
GEN7-37134 | Under some conditions, Content Filtering Service (CFS) DNS reply handling and request time out, which can trigger conflicts in the handling of cache timers and cause an unexpected ... | 2020-06-04 00:00:00 | Read more |
GEN7-37186 | When CASS is enabled, the Real-time Block List (RBL) filter is not hiding the RBL Filter settings. | 2020-06-04 00:00:00 | Read more |
GEN7-37221 | Sorting the NAT Policies list does not work as expected. | 2020-06-04 00:00:00 | Read more |
GEN7-37274 | The Send IKEv2 Cookie Notify setting is not functioning correctly and causes establishment of a IKEv2 VPN to fail. | 2020-06-04 00:00:00 | Read more |
GEN7-37417 | Deleting a user account with a domain format causes the error to be displayed: Network Object not found. | 2020-06-04 00:00:00 | Read more |
GEN7-37480 | The QR code is blank for RADIUS users while binding SSL VPN Time-based One-Time Password (TOTP) authentication. | 2020-06-04 00:00:00 | Read more |
GEN7-37783 | Devices are unable to negotiate IKE using 3rd Party Certificate VPN tunnel when using a certificate of a larger size because the DF flag forbids the fragmentation of the packet inv... | 2020-06-04 00:00:00 | Read more |
GEN7-38111 | SonicOS Stack-based Buffer Overflow Vulnerability. For more information, refer to CVE-2023-0656. | 2020-06-04 00:00:00 | Read more |
GEN7-38501 | A firewall with the watchdog settings enabled restarts itself every few minutes after updating to SonicOS 7.0.1-5108. | 2020-06-04 00:00:00 | Read more |
GEN7-35248 | Deleting the DHCPv6 prefix delegation for one interface will clear the prefix delegation configuration on another interface. | 2020-06-04 00:00:00 | Read more |
GEN7-36620 | After High Availability with Stateful Failover is set up, disabling then re-enabling Stateful Failover, and keeping the same Control and Data interfaces, will cause the secondary u... | 2020-06-04 00:00:00 | Read more |
GEN7-37326 | Editing the WAN GroupVPN settings, and then immediately enabling or disabling WAN GroupVPN, may cause some configuration settings to be lost. | 2020-06-04 00:00:00 | Read more |
GEN7-37501 | After the Deny Mac-Filter list containing a wireless client MAC is changed to No Mac Address, or if the Deny Mac-filter list has been disabled, the wireless client remains blocked. | 2020-06-04 00:00:00 | Read more |
GEN7-37511 | When configuring a gateway and adding a policy-based route using the 6to4AutoTunnel, an error is displayed: gateway must be default. | 2020-06-04 00:00:00 | Read more |
GEN7-26093 | SSL VPN will not work if DPI and Stateful Firewall Security is applied before enabling SSL VPN. | 2020-06-04 00:00:00 | Read more |
GEN7-31044 | A PPPoE connection will not connect until the firewall is restarted if the PPPoE connection is disconnected | 2020-06-04 00:00:00 | Read more |
GEN7-31454 | Firewall discovery and SSO failure may cause users to be disconnected from the internet when authenticated through Capture Client SSO and the client is unable to reach the Sonicwal... | 2020-06-04 00:00:00 | Read more |
GEN7-32128 | A User Login info initialization failure error may be intermittently displayed when trying to log in to the firewall using administrator credentials. | 2020-06-04 00:00:00 | Read more |
GEN7-32179 | Guest Accounts with a custom guest profile do not inherit its settings. | 2020-06-04 00:00:00 | Read more |
GEN7-32273 | With X0 and X1 paired in Transparent or L2Bridge mode, firewall diagnostics are not resolving DNS names because queries are being forwarded to the wrong interface. | 2020-06-04 00:00:00 | Read more |
GEN7-32426 | A FQDN that contains a hyphen cannot be used as a Syslog Server. | 2020-06-04 00:00:00 | Read more |
GEN7-32523 | One-to-one loopback NAT policies are not working as expected due to policy sequence prioritization. | 2020-06-04 00:00:00 | Read more |
GEN7-32542 | Using NetExtender or Mobile Connect SSL VPN, and then connecting to RDP server and launching a browser from the server, causes the SSL VPN session to be disconnected. | 2020-06-04 00:00:00 | Read more |
GEN7-32612 | An Undefined error message is displayed when more than three values are added in one Domain Key Pair in the CFS Default Profile > Custom header field. | 2020-06-04 00:00:00 | Read more |
GEN7-32827 | When upgrading from a previous version of SonicOS, the user needs to disable the port redundancy through the management user interface before upgrading the firmware on the firewall... | 2020-06-04 00:00:00 | Read more |
GEN7-32858 | A general LACP issue was seen in which PORT selection was being done incorrectly upon power up of the interface - issue was seen at boot up time. | 2020-06-04 00:00:00 | Read more |
GEN7-32875 | In an environment that uses Radius Accounting, and the firewall is configured to forward RADIUS Accounting requests to an unresponsive RADIUS accounting server, the CPU may reach h... | 2020-06-04 00:00:00 | Read more |
GEN7-32876 | In a High Availability environment, synchronization may cause NAT and Access Rules to revert to their previous settings on every failover. | 2020-06-04 00:00:00 | Read more |
GEN7-33142 | In Log Automation Health Check emails, the last character in the subject line is missing. | 2020-06-04 00:00:00 | Read more |
GEN7-33156 | SSL VPN connections may get saturated before the supported number of connection is reached. | 2020-06-04 00:00:00 | Read more |
GEN7-33391 | An LACP member port may ungroup the aggregation after ninety seconds for 10G interfaces under certain conditions. | 2020-06-04 00:00:00 | Read more |
GEN7-33533 | In a High Availability environment, frequent failovers may be seen when the peer was not receiving the heartbeat due to a legacy VPN option being enabled. | 2020-06-04 00:00:00 | Read more |
GEN7-33629 | A maximum of 100 devices can receive IP addresses from DHCP over VPN. | 2020-06-04 00:00:00 | Read more |
GEN7-33631 | The Numbered Tunnel interface packet scheduler was not handling traffic like SQL queries properly, causing out of order packets and slow throughput over the VPN. | 2020-06-04 00:00:00 | Read more |
GEN7-33721 | 10G links may intermittently not be up after the firewall is restarted. | 2020-06-04 00:00:00 | Read more |
GEN7-33847 | Download speeds may be much lower when Bandwidth Management is enabled using access rules. | 2020-06-04 00:00:00 | Read more |
GEN7-33857 | Connections for Avaya Phones may be dropped across a GVC VPN because all of the available IP addresses in the VPN IP Pool are assigned. Unused IP addresses were not being freed, so... | 2020-06-04 00:00:00 | Read more |
GEN7-33884 | In DHCP Scope Advanced Settings, setting a DHCP Generic Option object with the Option Number as 119 (from the DNS Domain Search List), it is not possible to add multiple DNS suffix... | 2020-06-04 00:00:00 | Read more |
GEN7-33915 | Settings migrated from a pre-next-generation firewall may cause NAT Policies to have duplicate UUID values. The firewall will display incorrect information when the NAT policy is e... | 2020-06-04 00:00:00 | Read more |
GEN7-33947 | Two-factor authentication may not work when a domain user tries to log into the firewall if a local non-domain user object exists that has the same name as the simple user name of ... | 2020-06-04 00:00:00 | Read more |
GEN7-33981 | All VPN policies are displayed as disabled if the VPN has been disabled and then re-enabled on the Settings tab on the Network > IPSec VPN > Rules and Settings page. | 2020-06-04 00:00:00 | Read more |
GEN7-34104 | When Content Filtering Service (CFS) and DPI-SSL are enabled, trying to access a website using a client with a proxy enabled causes the passphrase or confirm action not to be displ... | 2020-06-04 00:00:00 | Read more |
GEN7-34176 | The Virtual Office page does not display if L3 Flood Protection is set to Always proxy WAN Connections. | 2020-06-04 00:00:00 | Read more |
GEN7-34202 | Pages will fail to display in the management interface if an address group is created with the name exit. | 2020-06-04 00:00:00 | Read more |
GEN7-34270 | FTP Log automation will fail if the server response takes more than 2 seconds. | 2020-06-04 00:00:00 | Read more |
GEN7-34478 | When opening the VPN settings, the error An error has occurred but the cause could not be determined at this time. displayed when importing a configuration that contains a tab char... | 2020-06-04 00:00:00 | Read more |
GEN7-34699 | Migrated settings that have a trailing tab character in the Zone name will cause the Real-Time Charts to display no data. | 2020-06-04 00:00:00 | Read more |
GEN7-34703 | The status of a redundant X1 port is displayed as Offline on the Home > Dashboard > System > Device page. | 2020-06-04 00:00:00 | Read more |
GEN7-34852 | When upgrading to SonicOS 7.0.1-5080 with the current settings, the console shows displays the message Boot up from FACTORY DEFAULT!, but the firewall correctly restarts with the c... | 2020-06-04 00:00:00 | Read more |
GEN7-35233 | Upgraded jQuery. | 2020-06-04 00:00:00 | Read more |
GEN7-35489 | The UDP Inactivity Timeout value on access rules resets to 30 seconds even after being updated. | 2020-06-04 00:00:00 | Read more |
GEN7-35600 | When logging in with limited, read-only, or guest administrator user credentials, an error is displayed when accessing the Local User and Groups page. | 2020-06-04 00:00:00 | Read more |
GEN7-35617 | The 10G SFP High Availability interface link displays No link after the firewall restarts | 2020-06-04 00:00:00 | Read more |
GEN7-35690 | Adding a service object with the same name, but using a different case of letters as an existing service object, will cause the new service object to be auto-added to any service g... | 2020-06-04 00:00:00 | Read more |
GEN7-35769 | DNS Diagnostic does not use static DNS Proxy Cache entries when DNS Proxy is enabled when Enforce DNS Proxy For All DNS Requests is enabled. | 2020-06-04 00:00:00 | Read more |
GEN7-36107 | If a Deny category or URL is configured in security policy, the firewall does not send the block page to the client device. | 2020-06-04 00:00:00 | Read more |
GEN7-36188 | The Firewall Management user interface and command-line interface (CLI) becomes intermittently inaccessible, but traffic continues to pass through the firewall. | 2020-06-04 00:00:00 | Read more |
GEN7-33905 | Journal logs cannot be enabled to be persistent from within SonicOS. | 2020-06-04 00:00:00 | Read more |
GEN7-35285 | The packet monitor drop-down packet details may display information that is not related to the packet | 2020-06-04 00:00:00 | Read more |
GEN7-35640 | Traffic is not distributed as expected after a failover when using source and destination IP address binding in Round Robin-based WAN Load Balancing. | 2020-06-04 00:00:00 | Read more |
GEN7-35775 | The Local CFS server Current Using option is always the Primary server even if the Primary is not reachable. | 2020-06-04 00:00:00 | Read more |
GEN7-35841 | The Delete items from the list button does not work for IPS Signature/Category List objects. | 2020-06-04 00:00:00 | Read more |
GEN7-36035 | The firewall console displays Error with HW UNIT when starting up. The messages are benign and can be ignored. | 2020-06-04 00:00:00 | Read more |
GEN7-36118 | When downloading the Tech Support Report, the console displays wlanWriteDumpToTsr cannot access. The messages are benign and the TSR is able to be downloaded. | 2020-06-04 00:00:00 | Read more |
GEN7-36333 | When using the command-line (CLI) instruction import cli terminal merge best-effort, management should not be attempted from the web management interface until the process finishes... | 2020-06-04 00:00:00 | Read more |
GEN7-28170 | Appflow Reports displays the incorrect number of threats for GAV, Anti-Spyware, Intrusion Prevention, and Applications. | 2020-06-04 00:00:00 | Read more |
GEN7-31592 | Opening up a new tab by right-clicking on an existing browser tab showing Interfaces and then clicking Duplicate may display the error Invalid authentication: SN and EPAID do not m... | 2020-06-04 00:00:00 | Read more |
GEN7-32232 | The VPN tunnel interface may periodically become inactive with IKE response packets dropped due to IKE packets from the stack not allowed in Policy Mode. | 2020-06-04 00:00:00 | Read more |
GEN7-32518 | Slow throughput may be experienced during TFTP. | 2020-06-04 00:00:00 | Read more |
GEN7-32882 | Slow web traffic over IPSec VPN may be experienced with ESP packets dropped by the remote firewall because of an error in the checksum when the tunnel VPN is established on the sla... | 2020-06-04 00:00:00 | Read more |
GEN7-33499 | Application Security Policies may not function correctly when App Group indexes are not set correctly when objects are first created after registration. | 2020-06-04 00:00:00 | Read more |
GEN7-33612 | A Guest account may be able to access the internet after the account session time has been expired | 2020-06-04 00:00:00 | Read more |
GEN7-33643 | When editing the administration privilege of local users, the updates are not displayed on Local Users page. | 2020-06-04 00:00:00 | Read more |
GEN7-33748 | When Virtual MAC is enabled, during transition from primary to backup in a High Availability configuration, the standby appliance uses the shared IP to generate ARP broadcasts. | 2020-06-04 00:00:00 | Read more |
GEN7-33848 | SlowTFTP traffic may be experienced when traversing the firewall. Option ACK messages are dropped by the firewall when received on different blades than the Read Request Forward bl... | 2020-06-04 00:00:00 | Read more |
GEN7-34183 | In a High Availability environment, the default routes for the directly connected interfaces are not synchronized to the secondary device. | 2020-06-04 00:00:00 | Read more |
GEN7-34397 | SNMP packets are dropped with the error NAT policy generate unique remap port failed due to incorrect multi-blade traffic handling for SNMP traffic. | 2020-06-04 00:00:00 | Read more |
GEN7-34773 | DPI-SSL may intermittently not be enforced. | 2020-06-04 00:00:00 | Read more |
GEN7-34774 | The Don't redirect unauthenticated users to log in setting in the Action Profile object does not function as expected. Unauthenticated users are not bypassed from user-specific pol... | 2020-06-04 00:00:00 | Read more |
GEN7-35294 | Security Policy Block Page for Website Category blocking for authenticated user displays different Security Policies instead of the higher-priority Security Policy for Authenticate... | 2020-06-04 00:00:00 | Read more |
GEN7-35491 | The firewall may not initiate Single Sign-on (SSO) consistently on denied websites when the Zone-based SSO is set to Enforced. | 2020-06-04 00:00:00 | Read more |
GEN7-35786 | The sorted order of items is incorrect when sorting NAT policies by Name, Created, or Updated. | 2020-06-04 00:00:00 | Read more |
GEN7-35966 | Single Sign-on (SSO) was not triggered for SSO enforcement before detecting that it is needed by the policies. | 2020-06-04 00:00:00 | Read more |
GEN7-36980 | ICMP traffic fails over a numbered tunnel interface when the packets are larger than 1472 because the remote firewall receives an incorrect checksum. | 2020-06-04 00:00:00 | Read more |
GEN7-37069 | Cannot export Security Policies to a CSV file. | 2020-06-04 00:00:00 | Read more |
GEN7-37070 | Sorting NAT Policies by Hits and other new columns does not function as expected. | 2020-06-04 00:00:00 | Read more |
GEN7-37633 | Connections fail over SSL-VPN with users using Two-Factor authentication in addition to RADIUS authentication. | 2020-06-04 00:00:00 | Read more |
GEN7-38154 | SonicOS Stack-based Buffer Overflow Vulnerability. For more information, refer to CVE-2023-0656. | 2020-06-04 00:00:00 | Read more |
GEN7-31899 | The configuration on the DOS Policy page cannot be edited. | 2020-06-04 00:00:00 | Read more |
GEN7-37532 | The active unit in a High Availability configuration shows the same MGMT IP for both the Primary and Secondary appliances. | 2020-06-04 00:00:00 | Read more |
GEN7-29975 | The ESP packet is dropped by the remote firewall because of an error in the checksum when the tunnel VPN is established on the slave blade of the device when management traffic is ... | 2020-06-04 00:00:00 | Read more |
GEN7-30535 | Changing the setting of the Enable checkbox for a Syslog Server entry may cause a full preference synchronization to the backup unit in an High Availability environment. | 2020-06-04 00:00:00 | Read more |
GEN7-30559 | A reboot is seen during LDAP import of a large number of users. | 2020-06-04 00:00:00 | Read more |
GEN7-30710 | If an SSH session goes into configuration mode, and performs a commit for another configuration while a prior SSH session configuration commit is still in process, a deadlock state... | 2020-06-04 00:00:00 | Read more |
GEN7-30858 | When selecting an interface to reserve for multi-instance, the error message Command 'reserve interface Xnn' does not match where nn = interface you want to reserve. may be display... | 2020-06-04 00:00:00 | Read more |
GEN7-31091 | SSO via Capture Client using Endpoint Security Enforcement login is not working when SSO login via Endpoint Security is enabled. The user login authentication page is displayed whe... | 2020-06-04 00:00:00 | Read more |
GEN7-31119 | On the Packet Monitor and Connection Monitor pages, some initiator and responder routes are getting swapped in the display. | 2020-06-04 00:00:00 | Read more |
GEN7-31487 | Synchronization of OSPF route updates from master to slave blades may fail. | 2020-06-04 00:00:00 | Read more |
GEN7-31807 | Default address objects cannot be deleted for interfaces that are not assigned. | 2020-06-04 00:00:00 | Read more |
GEN7-31855 | Changing the OSPF timer interval changes the authentication password and causes OSPF to stop operating. | 2020-06-04 00:00:00 | Read more |
GEN7-31911 | Connectivity issues may be experienced due to inconsistencies in the OSPF route blade synchronization. | 2020-06-04 00:00:00 | Read more |
GEN7-31919 | Using the boot current firmware with a local backup configuration may fail in a High Availability environment. After the firewalls restart, the configuration has not been updated. | 2020-06-04 00:00:00 | Read more |
GEN7-32062 | SNMPv2 packets are being dropped as IP Spoof, but SNMPv3 packets are not. | 2020-06-04 00:00:00 | Read more |
GEN7-32096 | Information sent to Analytics is reporting only one-fourth of the Active Connections and App Bandwidth than what is displayed directly in the System Monitor data for the firewall. | 2020-06-04 00:00:00 | Read more |
GEN7-32102 | The Capture ATP scan History may intermittently disappear on a firewall in High Availability environment. | 2020-06-04 00:00:00 | Read more |
GEN7-32117 | Connections may be dropped in a High Availability environment due to dynamic route blade and High Availability synchronization issues. | 2020-06-04 00:00:00 | Read more |
GEN7-32118 | After failover in a High Availability environment, the secondary unit is not able to maintain OSPF adjacency with its peers and all routing entries may be lost. | 2020-06-04 00:00:00 | Read more |
GEN7-32129 | After disabling source port remap under NAT, a firewall may drop traffic with the error NAT policy generate unique remap port failed. Traffic originating from the X0 interface work... | 2020-06-04 00:00:00 | Read more |
GEN7-32197 | OSPF remains in an inactive state and the Designated Router fails to initiate link-state advertisement (LSA) after failover in a High Availability environment. | 2020-06-04 00:00:00 | Read more |
GEN7-32244 | Some OSPF routing entries persist even after relevant OSPF neighbor has been inactive for a period of time. | 2020-06-04 00:00:00 | Read more |
GEN7-32253 | Connectivity issues may be experienced due to inconsistencies in the OSPF route blade synchronization. | 2020-06-04 00:00:00 | Read more |
GEN7-32324 | Adding a chassis secondary IP on a Secondary firewall produces the error message Chassis IP and Secondary Chassis IP overlap , | 2020-06-04 00:00:00 | Read more |
GEN7-32661 | In a High Availabilty environment when performing Failover/Failback, that OSPF Originate Default Route may stop working. | 2020-06-04 00:00:00 | Read more |
GEN7-32691 | Scheduling a backup for FTP settings may cause a file to be generated with 0 Bytes. | 2020-06-04 00:00:00 | Read more |
GEN7-32779 | Configuring a static IPv6 WAN interface produces the error message Error: Command 'dns primary 2002:4860::8888' does not match. A condition is missing to disable the DNS fields for... | 2020-06-04 00:00:00 | Read more |
GEN7-33236 | Sending TSR/Settings by FTP via Mixed Schedule did not trigger the transfer if the one-time schedule was not matched. | 2020-06-04 00:00:00 | Read more |
GEN7-33365 | Nine-digit Common Vulnerabilities and Exposures (CVEs) are missing or invalid under Object -> Profile Objects -> Intrusion Prevention -> Intrusion Prevention Objects. | 2020-06-04 00:00:00 | Read more |
GEN7-33371 | The Factory Default Configuration button does not function. | 2020-06-04 00:00:00 | Read more |
GEN7-33473 | The CFS Confirm/Passhrass action does not redirect for websites that use a custom HTTP/ HTTPS port. | 2020-06-04 00:00:00 | Read more |
GEN7-33559 | Information sent to Analytics is reporting only one-fourth of the Active Connections and App Bandwidth than what is displayed directly in the System Monitor data for the firewall. | 2020-06-04 00:00:00 | Read more |
GEN7-33630 | Adding a new Security Policy fails to synchronize between the Active firewall and Standby firewall in a High Availability environment because the index value was not being returned... | 2020-06-04 00:00:00 | Read more |
GEN7-34409 | NAT Lookup fails after SonicOS restarts for NAT Policy when the NAT LB probe is in a failed state because it tries to create its own Network Monitor (default) policy, but its name ... | 2020-06-04 00:00:00 | Read more |
GEN7-35041 | The last character of syslog messages and log messages is missing. | 2020-06-04 00:00:00 | Read more |
GEN7-28226 | When using the web management interface, the values in the table in the DHCP section cannot be sorted using the column headers. | 2020-06-04 00:00:00 | Read more |
GEN7-28491 | Using the special character "(" is not accepted in a VPN name. | 2020-06-04 00:00:00 | Read more |
GEN7-29640 | When importing settings using the Migration Tool, Switch settings are not imported. | 2020-06-04 00:00:00 | Read more |
GEN7-30386 | Group memberships set locally may not be displayed in the web management interface for an imported LDAP user associated with Any domain. | 2020-06-04 00:00:00 | Read more |
GEN&-30450 | An LDAP user cannot change their expired password using the Virtual Office portal. | 2020-06-04 00:00:00 | Read more |
GEN7-30509 | Booting uploaded firmware in a High Availability pair succeeds, but triggers an audit log that indicates that upload has failed. | 2020-06-04 00:00:00 | Read more |
GEN7-30836 | When a login fails through a mobile connection on a password change that did not meet the requirements, subsequent connections will fail until the original SSL session times out. | 2020-06-04 00:00:00 | Read more |
GEN7-30874 | An Aggressive mode VPN Tunnel on a DHCP WAN interface does not negotiate after the network security appliance is restarted in a WAN Load Balancing environment. | 2020-06-04 00:00:00 | Read more |
GEN7-30959 | NetExtender may connect slowly and frequently disconnect when there is heavy SSL VPN usage. | 2020-06-04 00:00:00 | Read more |
GEN7-31374 | When the network security appliance is restarted, a new dynamic scope from 0.0.0.1 to 0.0.0.254 is created if W0 is under Native Bridge mode. | 2020-06-04 00:00:00 | Read more |
GEN7-31453 | Custom static routes are not automatically disabled when a WAN probe fails and goes into failover. | 2020-06-04 00:00:00 | Read more |
GEN7-31492 | A High Availability state synchronization can be triggered, causing the backup unit to restart, if the requested connection uses a WAN load-balanced interface. | 2020-06-04 00:00:00 | Read more |
GEN7-31588 | On the Device > Log > Settings page the toggle buttons to disable or apply to all categories whether a log is sent to a given resource does not work as expected. | 2020-06-04 00:00:00 | Read more |
GEN7-31660 | An UDP session was being enabled for RDP sessions connected through NetExtender, causing severe packets loss and, eventually, disconnection. | 2020-06-04 00:00:00 | Read more |
GEN7-31760 | Settings cannot be exported after deleting or editing a custom zone. | 2020-06-04 00:00:00 | Read more |
GEN7-31820 | Link Aggregation Control Protocol (LACP) does not function as expected on interfaces above X32. | 2020-06-04 00:00:00 | Read more |
GEN7-31846 | Configuring Bandwidth Management and using Tunnel All mode in SSL VPN may degrade throughput on the network security appliance. | 2020-06-04 00:00:00 | Read more |
GEN7-31850 | Custom Routes on the WAN are not disabled when the WAN Logical Probes Fail in a WAN Load Balancing setup. | 2020-06-04 00:00:00 | Read more |
GEN7-31884 | If more than one login to the command-line interface (CLI) using SSH is attempted simultaneously when using RADIUS, LDAP, or TACACS+ authentication, the user groups list may no lon... | 2020-06-04 00:00:00 | Read more |
GEN7-31900 | Configuration changes on the DoS Action Profile page are not listed in the log files and cannot be audited. | 2020-06-04 00:00:00 | Read more |
GEN7-31907 | Some third-party switches may have different default configurations for 1000BASE-X auto-negotiation without the option to bypass auto-negotiation, which may cause the connection to... | 2020-06-04 00:00:00 | Read more |
GEN7-31909 | The User Status page does not display the active Terminal Services Agent (TSA) identified users. | 2020-06-04 00:00:00 | Read more |
GEN7-32311 | DPI-SSL does not work properly when an interface is in Layer 2 bridge mode and when the Never route traffic on this bridge-pair option is disabled. | 2020-06-04 00:00:00 | Read more |
GEN7-32325 | The SSL VPN portal displays multiple domains incorrectly in the drop-down list. | 2020-06-04 00:00:00 | Read more |
GEN7-32331 | With the maximum number of SSH sessions established and new sessions being attempted, the SSH daemon thread and web server may stop working if a change to the interface or a simila... | 2020-06-04 00:00:00 | Read more |
GEN7-32338 | The SonicWall DHCP server does not handle DHCP Relay Information Option (option 82) in the DHCP relay. | 2020-06-04 00:00:00 | Read more |
GEN7-32347 | A SNMP get of getDeviceInfo returns an invalid object identifier. | 2020-06-04 00:00:00 | Read more |
GEN7-32348 | A network security appliance may restart in a High Availability environment with a very large number of active users. | 2020-06-04 00:00:00 | Read more |
GEN7-32349 | A buffer underrun in the DP-engine might be seen in the Topology section of the web management interface. | 2020-06-04 00:00:00 | Read more |
GEN7-32549 | After an upgrade to the firmware, the SSL Server certificate may not be imported, causing the DPI-SSL server to stop working. | 2020-06-04 00:00:00 | Read more |
GEN7-32578 | Administrators may be unable to edit the Log Automation page when using a mixed schedule object. | 2020-06-04 00:00:00 | Read more |
GEN7-32602 | DNS packets may be dropped when UDP Flood Protection is running. | 2020-06-04 00:00:00 | Read more |
GEN7-32667 | After restoring the backup configuration, the WLAN PSK passphrase cannot be changed, displaying the error message: WLAN authentication type: Invalid. | 2020-06-04 00:00:00 | Read more |
GEN7-32718 | The settings of a WPA-state machine can become corrupted if a group key renewal occurs during an unscheduled update window. Wireless users may be unable to connect after the schedu... | 2020-06-04 00:00:00 | Read more |
GEN7-33058 | On the Users > Settings page, on the User Sessions tab, configuring For other unidentified connections to Log user name with a value that is 8 multiples of the value may cause an o... | 2020-06-04 00:00:00 | Read more |
GEN7-33083 | SNMP monitoring may not operate for secondary WAN interfaces. | 2020-06-04 00:00:00 | Read more |
GEN7-33237 | After importing settings, administrators may not be able to disable PortShield, resulting in the error: Failed: Disabled PortShield port cannot be switched out of PortShield. | 2020-06-04 00:00:00 | Read more |
GEN7-33361 | Forcing the speed of a 1G Copper port may cause link up issues. | 2020-06-04 00:00:00 | Read more |
GEN7-33489 | Forcing the speed of a 1G Copper port may cause link up issues. | 2020-06-04 00:00:00 | Read more |
GEN7-34407 | When a storage module is replaced, the firewall fails to start up and displays a fatal error. | 2020-06-04 00:00:00 | Read more |
GEN7-33502 | The Local and Peer IKE ID cannot be deleted on an IPv4 or IPv6 VPN policy | 2020-06-04 00:00:00 | Read more |
GEN7-33850 | PPPoE IPv6 WAN traffic may drop because IPV6 NDP entries are not getting updated. Restart the network security appliance. | 2020-06-04 00:00:00 | Read more |
GEN7-34391 | A client system may be unable to obtain an IPv6 address from a DHCP v6 Server through the IP-Helper relay policy. | 2020-06-04 00:00:00 | Read more |
GEN7-28720 | The Application Bandwidth Monitor may not report the full set of statistics. | 2020-06-04 00:00:00 | Read more |
GEN7-29262 | Traffic may fail to pass through the VPN tunnel interface for tunnel VPN policies established on non-master blades when the VPN is bound to a VLAN and parent interface of the VLAN ... | 2020-06-04 00:00:00 | Read more |
GEN7-29777 | The user interface is very slow when refreshing the User Group page with over 2800 user groups in it. | 2020-06-04 00:00:00 | Read more |
GEN7-30009 | Security Policies page shows No Data momentarily when loading over 600 entries. | 2020-06-04 00:00:00 | Read more |
GEN7-30412 | On the Users Status page, the Inactivity Remaining column may not display properly on the Users list. | 2020-06-04 00:00:00 | Read more |
GEN7-30459 | On LDAP User Import page, only the first LDAP Group displays any users when user groups are read from the LDAP Server. | 2020-06-04 00:00:00 | Read more |
GEN7-30599 | Unnecessary warning of the lock gBkupTaskMutex is displayed on console for tRemoteBackupd. | 2020-06-04 00:00:00 | Read more |
GEN7-30786 | In the web management interface, administrators cannot browse through the full list of NAT policies. | 2020-06-04 00:00:00 | Read more |
GEN7-30787 | Users are displayed as being inactive when traffic sourced from a user IP is crossing the network security appliance when SSO agent, TSA, or NTLM are enabled. | 2020-06-04 00:00:00 | Read more |
GEN7-30789 | A crash may be encountered on the primary network security appliance after disabling High Availability because of attempting to synchronize an SSO failure report to the master blad... | 2020-06-04 00:00:00 | Read more |
GEN7-31032 | The error Cannot read property 'id' of undefined displays when adding a custom match object. | 2020-06-04 00:00:00 | Read more |
GEN7-31138 | After a stateful High Availability failover, traffic may be interrupted for more than 10 seconds due to G-ARP not being captured on the client host system. | 2020-06-04 00:00:00 | Read more |
GEN7-31262 | The Content Filtering Service (CFS) server is not reachable from a standby unit in a High Availability pair because the request was not using the monitoring IP address of its relat... | 2020-06-04 00:00:00 | Read more |
GEN7-31289 | In a High Availability pair, the secondary unit may reboot due to settings becoming unsynchronized after clearing packet capture. | 2020-06-04 00:00:00 | Read more |
GEN7-31388 | In a High Availability configuration, and both Primary and Secondary Chassis IPs are configured, when the Primary firewall is removed from the High Availability mode, an error abou... | 2020-06-04 00:00:00 | Read more |
GEN7-31425 | In a High Availability configuration, with IPHelper enabled and the resolution set to DNS then NetBios, a Failover can eventually occur on the primary device, but remain stable on ... | 2020-06-04 00:00:00 | Read more |
GEN7-31625 | In a High Availability configuration, the primary unit's VLAN interface MAC address of a static LAG pair is being published also from the secondary unit's secondary LAG interface i... | 2020-06-04 00:00:00 | Read more |
GEN7-31636 | The Real-Time Monitor on the System Monitor tab may display gaps in the graphs of Multicore Monitor. | 2020-06-04 00:00:00 | Read more |
GEN7-31803 | SonicOS shuts down and reboots due to a segmentation fault. | 2020-06-04 00:00:00 | Read more |
GEN7-31805 | Stateful Synchronization requires 40 minutes to be ready after the Control Interface is unplugged or plugged in, resulting from the retransmission of High Availability settings syn... | 2020-06-04 00:00:00 | Read more |
GEN7-31835 | Enabling packet capture on the primary unit in a High Availability pair may trigger a segmentation fault and the secondary unit becomes stuck in High Availability synchronization m... | 2020-06-04 00:00:00 | Read more |
GEN7-31931 | In a High Availability configuration, the primary device may reboot while synchronizing the DHCP binding. | 2020-06-04 00:00:00 | Read more |
GEN7-32023 | Using packet capture or diagnostic tools on the primary unit in a High Availability pair triggers a synchronization of the settings. | 2020-06-04 00:00:00 | Read more |
GEN7-32032 | Importing settings may cause a lock issue on the Policy table. | 2020-06-04 00:00:00 | Read more |
GEN7-32163 | Some decryption policies are missing, and the order of the policies is changed, upon failover from a primary unit to a secondary unit in a High Availability pair. | 2020-06-04 00:00:00 | Read more |
GEN7-32540 | A crash may be seen with a stacktrace for DP-engine-0 in a High Availability Pair causing failover when running a heavy load of mixed traffic, UDP traffic, and OSPF routes when DPI... | 2020-06-04 00:00:00 | Read more |
GEN7-32620 | A crash may be seen with a stacktrace for delayedLog.c in a High Availability Pair causing failover when running a heavy load of mixed traffic, UDP traffic, and OSPF routes when DP... | 2020-06-04 00:00:00 | Read more |
GEN7-29058 | A wildcard FQDN object will not resolve subdomains unless a www FQDN object is also created. | 2020-06-04 00:00:00 | Read more |
GEN7-30021 | Incorrect IPv6 addresses are displayed for logged in users on the User Status page. | 2020-06-04 00:00:00 | Read more |
GEN7-30065 | Trying to manually log out users in the web management interface after they are populated and active displays the error: command 'killuser ...' does not match. | 2020-06-04 00:00:00 | Read more |
GEN7-30681 | The packet monitor settings on the standby firewall display the primary configuration instead of the runtime configuration. | 2020-06-04 00:00:00 | Read more |
GEN7-30716 | When importing settings for High Availability the error Failed to create cloned ifList is displayed because of a synchronization issue. | 2020-06-04 00:00:00 | Read more |
GEN7-30743 | The network security appliance may reboot when a command-line interface (CLI) stage was destroyed unexpectedly when accessing data. | 2020-06-04 00:00:00 | Read more |
GEN7-31244 | When trying to create decryption policy using an LDAP imported group, the error Cannot read properties of undefined (reading 'success') is displayed. | 2020-06-04 00:00:00 | Read more |
GEN7-31260 | The network security appliance may reboot when TSR is pulled on units in High Availability. | 2020-06-04 00:00:00 | Read more |
GEN7-31889 | Stack-based buffer overflow in SonicOS potentially resulting in Denial-of-Service (DoS). | 2020-06-04 00:00:00 | Read more |
GEN7-31890 | Potential exposure of sensitive information to an unauthorized user via SNMP. | 2020-06-04 00:00:00 | Read more |
GEN7-31990 | Potential exposure of Wireless Access Point (WAP) sensitive information via SNMP. | 2020-06-04 00:00:00 | Read more |
GEN7-31991 | Improper restriction of TCP communication channel potentially resulting in Denial-of-Service (DoS). | 2020-06-04 00:00:00 | Read more |
GEN7-31992 | Allocation of resources without limits or throttling can potentially result in HTTP DoS via the Content Filtering Service (CFS). | 2020-06-04 00:00:00 | Read more |
GEN7-31994 | Unnecessary tNetObjMgr stack traces are displayed on the console. | 2020-06-04 00:00:00 | Read more |
GEN7-32418 | The OpenSSL library can enter an infinite loop when parsing an invalid certificate, potentially resulting in Denial-of-Service (DoS). | 2020-06-04 00:00:00 | Read more |
GEN7-31421 | There is a maximum string length of 100 characters for the input fields for the source and destination addresses within the Monitor Filter tab for packet capturing. This is not eno... | 2020-06-04 00:00:00 | Read more |
GEN7-19015 | Cannot connect to Layer Two Tunneling Protocol (L2TP) with packets dropped as the packet does not match traffic selectors if the L2TP clients are behind a network address translati... | 2020-06-04 00:00:00 | Read more |
GEN7-19520 | An error may be displayed when accessing the Topology view when a large number of client systems are connected. | 2020-06-04 00:00:00 | Read more |
GEN7-24141 | New devices may not be acquired by Network Security Manager (NSM) that have settings for VoIP are imported from an older (pre-2020) device. | 2020-06-04 00:00:00 | Read more |
GEN7-26188 | The LED for LAN bypass does not work as expected. | 2020-06-04 00:00:00 | Read more |
GEN7-26488 | Native Bridge Mode Pair causes IP traffic drops from and between the paired VLAN interfaces and causes the firewall web management interface to become inaccessible. | 2020-06-04 00:00:00 | Read more |
GEN7-26726 | Purge option to delete log files from storage cannot be selected if two or more files are selected. | 2020-06-04 00:00:00 | Read more |
GEN7-28690 | In a High Availability configuration, a reboot may be seen due to a segmentation fault in DP-engine-1. | 2020-06-04 00:00:00 | Read more |
GEN7-28776 | The Virtual Office Bookmark tab is not visible when a MGMT-Only privilege is added to the SSLVPN Services group by adding a group, enabling Members go straight to the management UI... | 2020-06-04 00:00:00 | Read more |
GEN7-28888 | An SNMP query fails over a site-to-site VPN when network address translation (NAT) is enabled. | 2020-06-04 00:00:00 | Read more |
GEN7-29012 | When using external storage, the system logs file location changes from secondary storage to primary storage after the network security appliance is rebooted. | 2020-06-04 00:00:00 | Read more |
GEN7-29162 | When using migrated settings, the Path Selection Profile interface status displays Not Qualified for SD-WAN Group interfaces when using the default SLA class object. | 2020-06-04 00:00:00 | Read more |
GEN7-29210 | Unable to add 10 GB SFP+ interfaces for Port Mirroring. | 2020-06-04 00:00:00 | Read more |
GEN7-29376 | SonicWall Switches managed using a network security appliance and connected on a Trunk port are not receiving a DHCP IP address from its native Interface. | 2020-06-04 00:00:00 | Read more |
GEN7-29535 | Console prints tTimerTask stacktrace about every 1 hour. There is no functional effect. | 2020-06-04 00:00:00 | Read more |
GEN7-29547 | Slow response times may be experienced when accessing a RDP session using a Virtual Office bookmark. | 2020-06-04 00:00:00 | Read more |
GEN7-29552 | Unbinding the Time-based one-time password (TOTP) key from the User Login Status page did not work if the user password does not meet the complexity constraints. | 2020-06-04 00:00:00 | Read more |
GEN7-29603 | A WAN Group VPN shared secret is displayed incorrectly when administering the network security appliance using Network Security Manager (NSM). | 2020-06-04 00:00:00 | Read more |
GEN7-29650 | When trying to set up Quota limit for Radius or LDAP users, the message script is missing one or more 'exit' commands may be displayed. | 2020-06-04 00:00:00 | Read more |
GEN7-29853 | Settings are not saved when importing LDAP users and assigning the user quota on the Import page. | 2020-06-04 00:00:00 | Read more |
GEN7-29867 | Trying to add an All Deny access rule on the WAN > WAN page maybe display the error Rule Blocks Management Rule(s). | 2020-06-04 00:00:00 | Read more |
GEN7-29872 | Server DPI-SSL, the error message The server is not sending intermediate certificate may be displayed. | 2020-06-04 00:00:00 | Read more |
GEN7-29904 | The Test LED is not blinking on the Standby unit in a High Availability pair. | 2020-06-04 00:00:00 | Read more |
GEN7-29990 | The RDP SSL VPN Virtual Office bookmark setting Automatically login, Use SSL-VPN account credentials has been removed due to security concerns. | 2020-06-04 00:00:00 | Read more |
GEN7-30015 | TCP traffic fails to pass through the WAN zone native bridge interfaces when the destination IP address is not in the same subnet with the client system. | 2020-06-04 00:00:00 | Read more |
GEN7-30040 | Allocation of resources without limits or throttling can potentially result in HTTP DoS via the Content Filtering Service (CFS). | 2020-06-04 00:00:00 | Read more |
GEN7-30063 | When a Guest user is included in a group membership of Guest Administrator: The message Auto- Generate password" feature for isn't working according to the assigned Guest profile m... | 2020-06-04 00:00:00 | Read more |
GEN7-30334 | When saving the configuration of an LDAP user in Local Users & Groups, the message script is missing one or more 'exit' command might be displayed. | 2020-06-04 00:00:00 | Read more |
GEN7-30418 | Not able to change the Default target IP under WAN failover and Load balancing Probe settings if using 0.0.0.0. | 2020-06-04 00:00:00 | Read more |
GEN7-30590 | Importing settings fail and trigger a trace indicating a post file HTTP issue through the API. | 2020-06-04 00:00:00 | Read more |
GEN7-30620 | The VPN category is missing from the Category list in Application Control when trying enable a block for the VPN category. | 2020-06-04 00:00:00 | Read more |
GEN7-30698 | The Local User display can be very slow to refresh. Searching for local users causes the Local Users interface to become unresponsive when a large number of configured users are pr... | 2020-06-04 00:00:00 | Read more |
GEN7-31049 | When the Trusted Relay Agent Check is enabled, the Global VPN Client (GVC) client may become unresponsive in Acquiring IP status and the firewall fails to offer DHCP IP addresses. | 2020-06-04 00:00:00 | Read more |
GEN7-31069 | The SNMP Manager may be unable to get responses from an idle firewall in a High Availability pair over a VPN. | 2020-06-04 00:00:00 | Read more |
GEN7-31215 | The Suppress Automatic Access Rules Creation for a VPN Policy is not available. | 2020-06-04 00:00:00 | Read more |
GEN7-31313 | In WAN Load Balancing, the default gateway cannot be used as the default target IP address when all targets are set to 0.0.0.0. | 2020-06-04 00:00:00 | Read more |
GEN7-31334 | Log files stored on external storage cannot be deleted. | 2020-06-04 00:00:00 | Read more |
GEN7-31358 | NSA 6700 only: The LACP configuration fails on the 40GB Interface (X33). | 2020-06-04 00:00:00 | Read more |
GEN7-31361 | Unable to add or edit an WLAN interface when Only allow traffic generated by a SonicPoint/SonicWave is disabled. The error Command 'no auto-discovery' does not match is displayed. | 2020-06-04 00:00:00 | Read more |
GEN7-31420 | When the rendering of the BGP neighbor status exceeds approximately 32k bytes, the Settings page does not display correctly. | 2020-06-04 00:00:00 | Read more |
GEN7-31746 | Enabling Mirror LDAP user groups locally does not display the imported mirrored groups. | 2020-06-04 00:00:00 | Read more |
GEN7-31987 | Potential exposure of Wireless Access Point (WAP) sensitive information via SNMP. | 2020-06-04 00:00:00 | Read more |
GEN7-31988 | Potential exposure of sensitive information to an unauthorized user via SNMP. | 2020-06-04 00:00:00 | Read more |
GEN7-32041 | When AppFlow is enabled, CP core usage will spike and many fields report that CP core CPU usage remains at 100% for an extended period of time. | 2020-06-04 00:00:00 | Read more |
GEN7-32225 | The OpenSSL library can enter an infinite loop when parsing an invalid certificate, potentially resulting in Denial-of-Service (DoS). | 2020-06-04 00:00:00 | Read more |
GEN7-31724 | When using a custom authentication partition, it displays a user in the Unauthenticated Users list. If the partition is disabled or using the default authentication partition, it d... | 2020-06-04 00:00:00 | Read more |
GEN7-31926 | A SonicWall Switch becomes unreachable after its DHCP lease expires when added to a Dedicated Uplink topology. | 2020-06-04 00:00:00 | Read more |
GEN7-32258 | When the MSSP license is expired, the network security appliance always prompts that the system needs to restart. | 2020-06-04 00:00:00 | Read more |
GEN7-32411 | Network Security Manager (NSM) reports that the network security appliance is unregistered in MSSP mode, even when appliance is registered. | 2020-06-04 00:00:00 | Read more |
GEN7-32696 | As an administrator, closing the aggregator port in a L2 Link Aggregation Group (LAG) which uses DHCP causes traffic to fail to pass through.A | 2020-06-04 00:00:00 | Read more |
GEN7-30375 | A crash may be observed in configuration auditing timer when the device is rebooted. | 2020-06-04 00:00:00 | Read more |
GEN7-30332 | A crash was observed when accessing the IPv6 address cache with a mix of IPv4 and IPv6 users being repeatedly logged in and out. | 2020-06-04 00:00:00 | Read more |
GEN7-30022 | The Search field in the ARP table only allows for the entry of one character. | 2020-06-04 00:00:00 | Read more |
GEN7-29792 | Loading settings with several IPv6 VLANs configured causes devices configured in High Availability to continuously failover and failback. | 2020-06-04 00:00:00 | Read more |
GEN7-29623 | In L3 Port Aggregation, the Aggregate Port does not show the correct link state on the Dashboard page of the user interface. | 2020-06-04 00:00:00 | Read more |
GEN7-29620 | Changing verification security level on the SSO 3rd Party API Configuration Advanced page on the interface triggers an error message: Host name/IP Address: the host name/IP address... | 2020-06-04 00:00:00 | Read more |
GEN7-29593 | A memory leak from the SSO API was observed when returning multiple errors in response to an SSO API request with multiple users. | 2020-06-04 00:00:00 | Read more |
GEN7-29592 | Blade mismatch warnings are being seen for SSO API user authentication with large number of users. | 2020-06-04 00:00:00 | Read more |
GEN7-29590 | An intermittent crash is seen when adding SSO users via 3rd party API and IPv6 and IPv4 groups overlap while IPv4/IPv6 traffic is present. | 2020-06-04 00:00:00 | Read more |
GEN7-29415 | VLAN subinterface does not show correct MTU in the user interface when jumbo frames are enabled. | 2020-06-04 00:00:00 | Read more |
GEN7-29412 | When accessing the Dashboard the first time, the Front Panel widget does not show the interface status indicators. | 2020-06-04 00:00:00 | Read more |
GEN7-29246 | HA timeout customization changes were improved to help large configuration files synchronize between Active and Idle units. | 2020-06-04 00:00:00 | Read more |
GEN7-29150 | Default Service Objects for ICMPv6 are missing in the web management interface. | 2020-06-04 00:00:00 | Read more |
GEN7-28793 | Modifying 3rd party SSO API client settings results in error: Host name / IP address: The host name/IP address must be unique. | 2020-06-04 00:00:00 | Read more |
GEN7-28338 | A number of IPv6 SSO inefficiencies in the mechanism for inter-blade user sync requests were fixed (those which request other blades to send something back and then wait for it). | 2020-06-04 00:00:00 | Read more |
GEN7-20540 | Route Policy Details for source and destination routes are wrong on IPv6 connections page on the backup unit of a High Availability pair. | 2020-06-04 00:00:00 | Read more |
GEN7-28144 | Unable to export console logs using FTP from the console. Use SCP to transfer files. | 2020-06-04 00:00:00 | Read more |
GEN7-28238 | In WAN Load Balancing and Failover setup, traffic flows from the backup WAN even when the Primary is at the Rank 1 and active after a cold boot or a firmware upgrade. Swap the rank... | 2020-06-04 00:00:00 | Read more |
GEN7-28269 | Deploying NSv on Azure to an existing VNET does not associate NSG to the X1 WAN subnet. Manually configure NSG on the existing WAN subnet or on the NSv X1 interface. | 2020-06-04 00:00:00 | Read more |
GEN7-28360 | When Failover and Load Balancing is disabled, failover does not occur when shutting down the primary WAN. | 2020-06-04 00:00:00 | Read more |
GEN7-28384 | Unable to configure the interface in Portshield to WLAN zone | 2020-06-04 00:00:00 | Read more |
GEN7-28388 | Trying to configure the fiber interfaces on the Portshield Port Graphics page causes the error Command 'link-speed auto-negotiate' does not match to be displayed. | 2020-06-04 00:00:00 | Read more |
GEN7-28397 | Link Aggregation Control Protocol (LACP) on 40GB Interfaces (X33) fails after rebooting NSa 6700 devices. | 2020-06-04 00:00:00 | Read more |
GEN7-28463 | WLB Type Spillover is working with interfaces in reverse of how it is configured. | 2020-06-04 00:00:00 | Read more |
GEN7-31534 | NSv series only: Improper restriction of TCP communication channel potentially resulting in DoS | 2020-06-04 00:00:00 | Read more |
GEN7-31742 | NSv series only: Potential exposure of sensitive information to an unauthorized user via SNMP | 2020-06-04 00:00:00 | Read more |
GEN7-31870 | NSa series, NSsp series, TZ series: Potential exposure of Wireless Access Point (WAP) sensitive information via SNMP | 2020-06-04 00:00:00 | Read more |
GEN7-31996 | NSv series only: Allocation of resources without limits or throttling can potentially result in HTTP DoS via the Content Filtering Service (CFS) | 2020-06-04 00:00:00 | Read more |
GEN7-31997 | NSa series, NSsp series, TZ series: Stack-based buffer overflow in SonicOS potentially resulting in DoS | 2020-06-04 00:00:00 | Read more |
GEN7-30684 | Offline registration on KVM using a manual keyset fails. | 2020-06-04 00:00:00 | Read more |
GEN7-30532 | Core 0 gradually increases to 100% utilization after about 12 hours. | 2020-06-04 00:00:00 | Read more |
GEN7-30420 | High Availability with Stateful Failover-enabled connections may not be fully being synchronized between active and standby units. | 2020-06-04 00:00:00 | Read more |
GEN7-30388 | High Availability units may stop responding and fail over to Secondary, reporting a DP crash. | 2020-06-04 00:00:00 | Read more |
GEN7-30385 | After importing Settings migrated from an NSa 3600 to an NSa 3700, navigating to the NAT page displays the error: An error has occurred but the cause could not be determined at thi... | 2020-06-04 00:00:00 | Read more |
GEN7-29639 | When a Bridge member is bound bind to a WAN interface and firewalling is enabled, the firewall cannot be accessed when the system pings the WAN subnet. All traffic, including LAN t... | 2020-06-04 00:00:00 | Read more |
GEN7-29637 | Incorrect values for memory usage may be reported when using SNMP. | 2020-06-04 00:00:00 | Read more |
GEN7-29383 | Firewall appliances may stop responding. | 2020-06-04 00:00:00 | Read more |
GEN7-29051 | In a Stateful Failover configuration, the active firewall may be unable to send cache remove packets to an idle firewall, reporting No buffer, causing connection cache to increase ... | 2020-06-04 00:00:00 | Read more |
GEN7-29048 | A firewall may drop valid traffic as IP spoof dropped over point-to-point connections with probing enabled on a policy-based route. | 2020-06-04 00:00:00 | Read more |
GEN7-29043 | Client DPI-SSL may cause high CPU utilization. | 2020-06-04 00:00:00 | Read more |
GEN7-29007 | Changing the maximum transmission unit (MTU) of a Virtual interface fails without displaying an error. | 2020-06-04 00:00:00 | Read more |
GEN7-28979 | The Exclusion Group setting on App Control changes to None when the device is restarted. | 2020-06-04 00:00:00 | Read more |
GEN7-28950 | Packet Monitor displays more packets than are selected in the Filter. | 2020-06-04 00:00:00 | Read more |
GEN7-28911 | Anti-Spam does not accept .local hostname under a LDAP server configuration of CASS. It fails with the error host name is empty or not valid. | 2020-06-04 00:00:00 | Read more |
GEN7-28861 | Transparent range host and range objects are not available in the Transparent Range drop-down list on the transparent interface configuration page when the primary WAN is set to an... | 2020-06-04 00:00:00 | Read more |
GEN7-28848 | A device registered offline with the signatures updated will not allow the creation of an Application Group. | 2020-06-04 00:00:00 | Read more |
GEN7-28847 | Border Gateway Protocol (BGP)-related access rules that were deleted are added again after when the device is restarted. An option on the Diagnostics page, Disable auto-added BGP a... | 2020-06-04 00:00:00 | Read more |
GEN7-28782 | A firewall appliance may stop responding intermittently. | 2020-06-04 00:00:00 | Read more |
GEN7-28762 | Some EICAR test files do not get blocked by Gateway Anti-Virus. | 2020-06-04 00:00:00 | Read more |
GEN7-28744 | Unable to create a cloud backup with the error Cloud backup service is unavailable. | 2020-06-04 00:00:00 | Read more |
GEN7-28682 | System logs file cannot be downloaded from the Secondary Storage. When the button to download the file is clicked, no popup window is displayed by the browser to save the file. | 2020-06-04 00:00:00 | Read more |
GEN7-28622 | When editing a multi-path route using unnumbered tunnel interfaces as the next hop interfaces, the error is displayed: interface x value is unreasonable. | 2020-06-04 00:00:00 | Read more |
GEN7-28535 | The error Enter a valid IPV4 addresss for default target in X1 is displayed when trying to change Load Balancing and Failover Group settings so the order of interfaces is different... | 2020-06-04 00:00:00 | Read more |
GEN7-28495 | SSL-VPN Services group is inheriting all VPN Access objects from its member users, | 2020-06-04 00:00:00 | Read more |
GEN7-28464 | Unable to add or edit an WLAN interface when Only allow traffic generated by a SonicPoint/SonicWave is disabled. Attempting to causes this error to be displayed: Command 'no auto-d... | 2020-06-04 00:00:00 | Read more |
GEN7-28447 | Communication between two subnets is not blocked by the Security policy when using secondary subnets on the same interface. | 2020-06-04 00:00:00 | Read more |
GEN7-28412 | E-mails on the mail server are sometimes not deleted and the connection to the mail server is not disconnected even if password-protected ZIP attachment files are detected as havin... | 2020-06-04 00:00:00 | Read more |
GEN7-28406 | When clicking the next arrow to items in the IP address column on the On Check Network Settings page of Diagnostics does not redirect to the setting spage for the specific server. | 2020-06-04 00:00:00 | Read more |
GEN7-28307 | The error Unknown Reason is displayed when configuring Local Users & Groups Settings page in Non-Config mode, | 2020-06-04 00:00:00 | Read more |
GEN7-28176 | The Guest Services configuration for Session Synchronization displays incorrect values in the web management interface and command-line interface (CLI). | 2020-06-04 00:00:00 | Read more |
GEN7-28148 | GroupList (DH) failed to generate after rebooting causing VPN to not come up. | 2020-06-04 00:00:00 | Read more |
GEN7-28123 | Data Plane Core utilization reaches 100% intermittently, causing the web management interface to lag and disrupting internet access to network hosts | 2020-06-04 00:00:00 | Read more |
GEN7-28038 | Possible buffer overflow that can be caused by an invalid parameter used by communication protocols between firewall and backend. | 2020-06-04 00:00:00 | Read more |
GEN7-27950 | Unable to manually add the parent switch to a High Availability pair, with this error: Index of the Extended Switch instance. | 2020-06-04 00:00:00 | Read more |
GEN7-27592 | The SSL-VPN RDP HTML5 Bookmark disconnects intermittently while resizing the window or itself without any changes. | 2020-06-04 00:00:00 | Read more |
GEN7-26764 | The Edit Lists selection box for Authentication Partition always shows Available Radius servers even of other types are chosen such, as SSO agents or LDAP servers. | 2020-06-04 00:00:00 | Read more |
GEN7-26758 | Transparent range displays address objects and address groups that are not part of WAN subnet. | 2020-06-04 00:00:00 | Read more |
GEN7-26447 | File location is not correct when Primary Storage is chosen for log storage. | 2020-06-04 00:00:00 | Read more |
GEN7-26136 | While connected using NetExtender, users may be frequently disconnected while trying to move, copy, open, or upload files to a shared drive. | 2020-06-04 00:00:00 | Read more |
GEN7-26089 | 100M/10M interface status shows "No link" after shutdown/no shutdown by toggling the Enabled button. Set Link Speed to Auto Negotiate or 1 Gbps Duplex. | 2020-06-04 00:00:00 | Read more |
GEN7-26063 | Auto-negotiation of multiple speeds might not work on the SFP/QSFP ports on NSsp 13700. | 2020-06-04 00:00:00 | Read more |
GEN7-24957 | An error is displayed with an undetermined cause the first time users log in using Two-Factor Authentication. | 2020-06-04 00:00:00 | Read more |
GEN7-24835 | Address Objects bound to a custom Public zone as well as Trusted zone are not displayed in the Transparent Range list while configuring an interface in Transparent Mode. | 2020-06-04 00:00:00 | Read more |
GEN7-24821 | Content Filtering policies block the web pages as expected, but firewall log events are not reporting any block messages and Analytics reporting shows that access to the website is... | 2020-06-04 00:00:00 | Read more |
GEN7-24658 | Blade synchronization issues may be seen when trying to log in using the default administrator credentials when using Two-Factor Authentication. | 2020-06-04 00:00:00 | Read more |
GEN7-15543 | On NSsp 15700 appliances, a BGP/OSPF neighbor cannot be established on a numbered VPN tunnel interface when the VPN policy is established on a non-master blade. | 2020-06-04 00:00:00 | Read more |
GEN7-13640 | Packet Monitor configuration is synchronized across a High Availability pair instead of being prevented. | 2020-06-04 00:00:00 | Read more |
GEN7-26344 | The network security appliance receives a signal to abort during restart, causing network interfaces to fail to establish links. | 2020-06-04 00:00:00 | Read more |
GEN7-27399 | The web management interface for a network security appliance becomes unavailable when using the X0 port. | 2020-06-04 00:00:00 | Read more |
GEN7-24501 | When Physical Monitoring only is enabled, the VLAN interface set as the primary WAN interface cannot failover after its parent interface is shut down. | 2020-06-04 00:00:00 | Read more |
GEN7-25650 | OSPF routes not showing as Active. | 2020-06-04 00:00:00 | Read more |
GEN7-26235 | Some changes on the Failover & LB pages cause unwanted reordering of LB Group values in the web management interface . | 2020-06-04 00:00:00 | Read more |
GEN7-26534 | Cannot change the logical probe settings to Physical monitoring and vice versa for WAN interfaces. | 2020-06-04 00:00:00 | Read more |
GEN7-26645 | Changes to the User Authentication Method are not being saved when selected under User Settings. | 2020-06-04 00:00:00 | Read more |
GEN7-26741 | Cannot delete unwanted address groups. | 2020-06-04 00:00:00 | Read more |
GEN7-26987 | After setting the VLAN ID to 3 (on the NETWORK > Firewall > Advanced > Internal VLAN page), DHCP requests are answered from X1 instead of X0, preventing access to the web managemen... | 2020-06-04 00:00:00 | Read more |
GEN7-26785 | If devices have Capture Client installed, Endpoint Enforcement does not allow access to the devices. | 2020-06-04 00:00:00 | Read more |
GEN7-27823 | Configuring Ratio mode for an LB group fails with an error message: Command 'rank 1' does not match. Use the command-line interface (CLI) to configure or change to ratio-based mode... | 2020-06-04 00:00:00 | Read more |
GEN7-27849 | An error is displayed when Group Always On is selected as the Exclusion Address for an App Control Policy type. | 2020-06-04 00:00:00 | Read more |
GEN7-26374 | High Availability is not working correctly on 10GB interfaces. The interface indicates that it is not connected. | 2020-06-04 00:00:00 | Read more |
GEN7-26816 | LAN Bypass is not set Off by default. | 2020-06-04 00:00:00 | Read more |
GEN7-26990 | Resetting the power while in Safe Mode during a Wipe process will put the network security appliance in an unrecoverable state. | 2020-06-04 00:00:00 | Read more |
GEN7-27207 | After enabling Override Speed, the Link Speed field is unavailable and cannot be set. | 2020-06-04 00:00:00 | Read more |
GEN7-16351 | When adding or editing an LDAP server on an NSsp 15700 with Authentication Partitioning enabled, there is no Partition field or option. | 2020-06-04 00:00:00 | Read more |
GEN7-21526 | After being disconnected, a second PPPoE connection does not connect until the firewall is rebooted. | 2020-06-04 00:00:00 | Read more |
GEN7-21977 | Adding, deleting, configuring or managing a Dell X-Series switch on an NSa 3700 does not work as expected and displays the error, "Error: Index of the Extended Switch Instance." | 2020-06-04 00:00:00 | Read more |
GEN7-22545 | Packet drops on WAN interface cause interruption in internet access. | 2020-06-04 00:00:00 | Read more |
GEN7-22706 | Detecting a SonicWall Switch beyond the first level in multi-level daisy chaining takes a long time. | 2020-06-04 00:00:00 | Read more |
GEN7-22772 | VLANs of the parent SonicWall Switch are not configured properly when using multi-level chaining. | 2020-06-04 00:00:00 | Read more |
GEN7-22826 | RDP service bookmark cannot be launched from the portal page in Internet Explorer and Safari browsers. | 2020-06-04 00:00:00 | Read more |
GEN7-22868 | LDAP user and user group import should not show users/groups that were previously imported. | 2020-06-04 00:00:00 | Read more |
GEN7-22950 | When updating signatures manually, the Signature File ID is incorrectly displayed as '3' in the POLICY | Security Services > Summary page. It should be '6'. | 2020-06-04 00:00:00 | Read more |
GEN7-22972 | A LAN PC cannot open an SSH Terminal session after disabling and then enabling SSH management on the X0 interface. | 2020-06-04 00:00:00 | Read more |
GEN7-23108 | The X1 interface cannot be enabled administratively after an NSv is registered using the manual keyset. | 2020-06-04 00:00:00 | Read more |
GEN7-23121 | After upgrading tenants to new firmware, the tenants end up in failed state after 1 to 2 hours. | 2020-06-04 00:00:00 | Read more |
GEN7-23168 | Serial Number and Auth Code should not be required when logging into the MySonicWall account after Manual Key Registration. | 2020-06-04 00:00:00 | Read more |
GEN7-23211 | On NSv, the Protocol page is missing in the WAN PPPoE interface edit window. | 2020-06-04 00:00:00 | Read more |
GEN7-23389 | DMZ Address Groups does not appear in the drop-down list on the firewall while configuring the interface in Transparent Mode. | 2020-06-04 00:00:00 | Read more |
GEN7-23408 | Anti-Spyware signatures are not enabled by globally enabling Prevent/Detect. | 2020-06-04 00:00:00 | Read more |
GEN7-23410 | When navigating to the Network > Zones page in the Classic user interface of a firewall running SonicOS 7.0.1, the user is redirected to the login page. | 2020-06-04 00:00:00 | Read more |
GEN7-23481 | When the portshield host port has no link, the PortShield Mode management traffic does not work on any other linked portshield member ports. | 2020-06-04 00:00:00 | Read more |
GEN7-23502 | There are issues with enabling and disabling interfaces. | 2020-06-04 00:00:00 | Read more |
GEN7-23504 | Change the default algorithm to AESGCM-256 for non GroupVPN policies. | 2020-06-04 00:00:00 | Read more |
GEN7-23526 | SSL VPN Virtual office RDP HTML5 bookmark does not work as expected. | 2020-06-04 00:00:00 | Read more |
GEN7-23583 | On NSsp 15700, there is a Security policy issue when using both Content Filter Service (CFS) and user level authentication. | 2020-06-04 00:00:00 | Read more |
GEN7-23793 | Additional gateways are not populated in a Multi-Path Route policy. | 2020-06-04 00:00:00 | Read more |
GEN7-23848 | The Match Object field is not populated when creating or editing a custom match. | 2020-06-04 00:00:00 | Read more |
GEN7-23911 | Route policies do not show correct address objects while trying to edit them. | 2020-06-04 00:00:00 | Read more |
GEN7-23957 | Portshielding a Switch interface (Switch 2) to a VLAN interface on uplink results in an error. | 2020-06-04 00:00:00 | Read more |
GEN7-24136 | Double interfaces are shown in the interface selection list during backend server communication. | 2020-06-04 00:00:00 | Read more |
GEN7-24137 | During backend server communication, selection of a specific interface does not work as expected, but always appears as ANY. | 2020-06-04 00:00:00 | Read more |
GEN7-24224 | Valid TCP packets with Urgent data are dropped. | 2020-06-04 00:00:00 | Read more |
GEN7-24458 | On NSv for AWS, APIs do not show custom tags and values. | 2020-06-04 00:00:00 | Read more |
GEN7-24521 | On NSv for AWS, AWS VPN does not show VPC details. | 2020-06-04 00:00:00 | Read more |
GEN7-24533 | Login fails with auto generated guest accounts and the error, "Module not ready" is reported. | 2020-06-04 00:00:00 | Read more |
GEN7-24577 | TCP Urgent - UI Implementation | 2020-06-04 00:00:00 | Read more |
GEN7-24741 | In DNS settings after selecting the Specify DNS Servers Manually option and clicking Accept, the selected option is changed to Inherit DNS Settings Dynamically from WAN Zone. | 2020-06-04 00:00:00 | Read more |
GEN7-25457 | On multi-blade NSsp, an error is displayed when enable/disable RIP/OSPF for a numbered tunnel interface. | 2020-06-04 00:00:00 | Read more |
GEN7-25770 | Adding a multi-path route policy failed when configuring a VPN tunnel interface as a non-first interface. | 2020-06-04 00:00:00 | Read more |
GEN7-25830 | The Use Address Object drop-down menu does not display the Address Object created by the user in the GATEWAY AV EXCLUSION LIST. | 2020-06-04 00:00:00 | Read more |
GEN7-26006 | Resolved a PCI Compliance failed issue with error "HTTP Security Header Not Detected" on SSL-VPN portal. | 2020-06-04 00:00:00 | Read more |
GEN7-26336 | With Virtual MAC addressing enabled, the firewall sends a Gratuitous ARP reply using the default MAC address after the interface renews its DHCP lease, resulting in the connection ... | 2020-06-04 00:00:00 | Read more |
GEN7-22389 | On NSsp 15700, the State Sync function displays a critical unexpected error that the Retransmit buffer's sequence number does not match the array element. | 2020-06-04 00:00:00 | Read more |
GEN7-23716 | When a user logs in with the admin credentials or with user credentials that have SonicOS administrator privileges and then navigates to the Network > Zones page, the user is lo... | 2020-06-04 00:00:00 | Read more |
GEN7-24864 | Local packet mirror does not take effect. | 2020-06-04 00:00:00 | Read more |
GEN7-25016 | External storage display is wrong in TSR and in the SonicOS web management interface. | 2020-06-04 00:00:00 | Read more |
GEN7-25712 | 25G Direct Attach Cables (DAC) might not auto-negotiate speed and/or error correction on the NSsp 13700 X24-X31 ports. | 2020-06-04 00:00:00 | Read more |
GEN7-26035 | OSPF becomes disabled on the unnumbered VPN tunnel interface after adding the link aggregation LAG's member when it is bound to a Layer 2 LAG port. | 2020-06-04 00:00:00 | Read more |
GEN7-26154 | PortShield is enabled by default when High Availability is enabled in Internal Settings. | 2020-06-04 00:00:00 | Read more |
GEN7-26204 | VPN policy does not show gateway and networks if quotes are used in the VPN name. | 2020-06-04 00:00:00 | Read more |
GEN7-26419 | On NSsp 15700, interface Link Speed is not configurable in the SonicOSX web management interface, but is configurable in the CLI. | 2020-06-04 00:00:00 | Read more |
GEN7-26444 | Log files stored in External Storage cannot be deleted when using the SonicOS web management interface. | 2020-06-04 00:00:00 | Read more |
GEN7-26465 | Included or Excluded Users/Groups settings of IPS Signature cannot be imported. | 2020-06-04 00:00:00 | Read more |
GEN7-26474 | Unable to set WAN IP manually on SonicOS Setup Guide page when using Firefox browser. | 2020-06-04 00:00:00 | Read more |
GEN7-26710 | On NSa 4700, NSa 6700 and NSsp 13700, not able to change partition in DEVICE | Users > Authentication Partition page for a newly added policy. | 2020-06-04 00:00:00 | Read more |
GEN7-26827 | On NSsp 13700, the 10G RJ45 interface (X16-X19) Link Speed auto-negotiates to 5 Gbps when the cable is more than 10 feet long. | 2020-06-04 00:00:00 | Read more |
GEN7-26871 | TSR does not show files present on the two storage devices. | 2020-06-04 00:00:00 | Read more |
GEN7-26888 | SonicOS web management certificate did not have CN content of Subject and Issuer after changing Certificate Selection settings. | 2020-06-04 00:00:00 | Read more |
GEN7-27038 | On NSa 4700/6700 or NSsp 13700, child LDAP servers are not shown in LDAP server list in the contemporary user interface. | 2020-06-04 00:00:00 | Read more |
SOSV-4228 | Entering a value that is too large into an OAEP hash method or OAEP MGF1 mask method using the API causes a "Data out of bounds" error. The error message persists even when using a... | 2020-06-04 00:00:00 | Read more |
SOSV-4062 | An address object cannot be deleted from a Geo-IP Custom List using the SonicOS API. | 2020-06-04 00:00:00 | Read more |
SOSV-4068 | CFS status always displays as "Ready" even while the CFS server is offline and there is no web traffic. | 2020-06-04 00:00:00 | Read more |
SOSV-3101 | The Edit CFS Policy dialog does not correctly display the current settings of all options. | 2020-06-04 00:00:00 | Read more |
SOSV-4477 | With Client DPI-SSL enabled, it is difficult to manage through HTTPS when downloading files and the download speed drops to 20K or lower. | 2020-06-04 00:00:00 | Read more |
SOSV-4483 | The Enable detection-only mode option for GAV does not work. | 2020-06-04 00:00:00 | Read more |
SOSV-4206 | Clicking the RESTART ZERO TOUCH TASK button does not change the Zero Touch configuration. | 2020-06-04 00:00:00 | Read more |
SOSV-5178 | On an NSv High Availability pair with L3 HA established and the Enable Stateful Synchronization option selected, the active firewall does not synchronize the stateful information, ... | 2020-06-04 00:00:00 | Read more |
SOSV-5166 | After disabling L3 High Availability in the primary firewall, the L3 HA settings on the secondary unit are not cleared. | 2020-06-04 00:00:00 | Read more |
SOSV-3896 | On an NSv High Availability pair in Azure with Preempt Mode enabled, the IP address of the secondary unit interface appears in both the active and standby firewalls. | 2020-06-04 00:00:00 | Read more |
SOSV-3963 | The DHCP IP Helper function does not work over a site-to-site VPN tunnel. A DHCP client cannot obtain an IP address when IP Helper is used to configure the DHCP server in the peer ... | 2020-06-04 00:00:00 | Read more |
SOSV-4341 | For SD-WAN connections, the connection logs for the ABR Category ID incorrectly shows the PSP in the ABR Category Id section. For SD-WAN connections with SD-WAN ABR routes, the ABR... | 2020-06-04 00:00:00 | Read more |
SOSV-4211 | An allowed user is not redirected to an HTTPS server when the server is behind the peer firewall of a site-to-site VPN tunnel. After opening a new browser tab and accessing the ser... | 2020-06-04 00:00:00 | Read more |
SOSV-3613 | A VPN tunnel goes down and cannot establish after adding an advanced IPv6 address for X1. Occurs when configuring X1 and X0 on an NSv and a remote NSv with one IPv6 address, then c... | 2020-06-04 00:00:00 | Read more |
SOSV-5522 | 'Unbind TOTP code' is not working for domain / Imported users. | 2020-06-04 00:00:00 | Read more |